Evaluating Nanoparticle Breakthrough during Drinking Water Treatment
نویسندگان
چکیده
BACKGROUND Use of engineered nanoparticles (NPs) in consumer products is resulting in NPs in drinking water sources. Subsequent NP breakthrough into treated drinking water is a potential exposure route and human health threat. OBJECTIVES In this study we investigated the breakthrough of common NPs--silver (Ag), titanium dioxide (TiO2), and zinc oxide (ZnO)--into finished drinking water following conventional and advanced treatment. METHODS NPs were spiked into five experimental waters: groundwater, surface water, synthetic freshwater, synthetic freshwater containing natural organic matter, and tertiary wastewater effluent. Bench-scale coagulation/flocculation/sedimentation simulated conventional treatment, and microfiltration (MF) and ultrafiltration (UF) simulated advanced treatment. We monitored breakthrough of NPs into treated water by turbidity removal and inductively coupled plasma-mass spectrometry (ICP-MS). RESULTS Conventional treatment resulted in 2-20%, 3-8%, and 48-99% of Ag, TiO2, and ZnO NPs, respectively, or their dissolved ions remaining in finished water. Breakthrough following MF was 1-45% for Ag, 0-44% for TiO2, and 36-83% for ZnO. With UF, NP breakthrough was 0-2%, 0-4%, and 2-96% for Ag, TiO2, and ZnO, respectively. Variability was dependent on NP stability, with less breakthrough of aggregated NPs compared with stable NPs and dissolved NP ions. CONCLUSIONS Although a majority of aggregated or stable NPs were removed by simulated conventional and advanced treatment, NP metals were detectable in finished water. As environmental NP concentrations increase, we need to consider NPs as emerging drinking water contaminants and determine appropriate drinking water treatment processes to fully remove NPs in order to reduce their potential harmful health outcomes.
منابع مشابه
Application of in vivo measurements for the management of cyanobacteria breakthrough into drinking water treatment plants.
The increasing presence of potentially toxic cyanobacterial blooms in drinking water sources and within drinking water treatment plants (DWTPs) has been reported worldwide. The objectives of this study are to validate the application of in vivo probes for the detection and management of cyanobacteria breakthrough inside DWTPs, and to verify the possibility of treatment adjustment based on inten...
متن کاملHydraulic Properties of Porous Media Saturated with Nanoparticle-Stabilized Air-Water Foam
The foam generated by the mixture of air and water has a much higher viscosity and lower mobility than those of pure water or gas that constitutes the air-water foam. The possibility of using the air-water foam as a flow barrier for the purpose of groundwater and soil remediation is explored in this paper. A nanoparticle-stabilized air-water foam was fabricated by vigorously stirring the nano-f...
متن کاملAssessment of waterborne protozoan passage through conventional drinking water treatment process in Venezuela.
Three drinking water treatment plants (DWTPs) differing in source water and treatment capacity were investigated for the potential passage of waterborne protozoan (oo)cysts through conventional processing. DWTP I (15,000 L/s), DWTP II (7,500 L/s) and DWTP III (4,300 L/s) provide drinking water for approximately 2.7 million inhabitants of the Metropolitan District of Caracas (Venezuela). The US ...
متن کاملEvaluating hydrogeochemistry and turbidity problem of a carbonate aquifer, Shiraz, Iran
Important karstic aquifers exist in west and southwest of Iran. Mansour-Abad Karstic region is located in Shiraz, southwest of Iran. It supplies the drinking water for the whole area by 4 pumping water wells, some of which have water turbidity problem. The present research aims to assess the hydrogeochemistry and turbidity problem in the karstic water production wells. The EC varies between 703...
متن کاملEquilibrium, kinetics and breakthrough studies for adsorption of fluoride on activated alumina
Contamination of drinking water due to fluoride is a severe health hazard problem. Excess of fluoride (>1.5mg/l) in drinking water is harmful to the human health. Various treatment technologies for removing fluoride from groundwater have been investigated in the past. Present investigation aims to remove fluoride by activated alumina. Adsorption isotherm has been modeled by Langmuir equation an...
متن کامل