Technical factors for success with metal ring acetabular reconstruction.
نویسندگان
چکیده
Sixty-four hips in 62 patients were revised with a Mueller ring (28 hips), Ganz ring (18 hips), and Burch-Schneider cage (18 hips) under the direction of a single surgeon. A polyethylene cup was cemented into the metal support of all hips. Average follow-up was 4.6 years (range, 2.0-6.7 years). Six rings were revised because of aseptic loosening, and 5 others were radiographically loose, for a mechanical failure rate of 11 of 64 (17%). Acetabular metal ring supports failed by migration when defects of > or =60% of the superior weight-bearing bone were filled by only cement or particulate graft. At the time of surgery, the superior rim of the metal support should be against host-bone for 60% of its support, and if not, the use of bulk allograft, rather than particulate graft, is required. Dislocation was the second failure mechanism identified, and this occurred in 15 hips (23%), with reoperation required in 5 hips (8%). A constrained liner should be used in patients with nonunion of the trochanter and preoperative abductor weakness that grades fair/minus or worse as measured by the side-lying abduction test.
منابع مشابه
A modified custom-made triflanged acetabular reconstruction ring (MCTARR) for revision hip arthroplasty with severe acetabular defects.
The treatment of extensive acetabular bone loss and pelvic discontinuity in revision total hip arthroplasty remains challenging. We report our preliminary experience with the modified custom-made triflanged acetabular reconstruction ring (MCTARR) in the management of such situations. The MCTARR is a custom-made metal reinforcement ring with a trabecular surface to encourage bone ingrowth and a ...
متن کاملAcetabular Reconstruction in Total Hip Arthroplasty
The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component select...
متن کاملCementless Acetabular Reconstruction for Arthropathy in Old Acetabular Fractures.
This study was conducted to identify the factors influencing mechanical failure of cementless acetabular reconstruction for arthropathy after operative treatment of acetabular fractures. Fifty-six patients (56 hips) undergoing cementless total hip arthroplasty were enrolled and followed for a mean of 120 months (range, 60-180 months). The 10-year survival rate, with mechanical failure (radiogra...
متن کاملReconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement
Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...
متن کاملThe management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components.
We investigated the early results of modular porous metal components used in 23 acetabular reconstructions associated with major bone loss. The series included seven men and 15 women with a mean age of 67 years (38 to 81), who had undergone a mean of two previous revisions (1 to 7). Based on Paprosky's classification, there were 17 type 3A and six type 3B defects. Pelvic discontinuity was noted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 16 8 شماره
صفحات -
تاریخ انتشار 2001