Electrochemical oxidation of ochratoxin A at a glassy carbon electrode and in situ evaluation of the interaction with deoxyribonucleic acid using an electrochemical deoxyribonucleic acid-biosensor.

نویسندگان

  • S C B Oliveira
  • V C Diculescu
  • G Palleschi
  • D Compagnone
  • A M Oliveira-Brett
چکیده

Ochratoxin A (OTA) is a fungal metabolite that occurs in foods, beverages, animal tissues, human blood and presents carcinogenic, teratogenic and nephrotoxic properties. This study concerns the redox properties of OTA using electrochemical techniques which have the potential for providing insights into the biological redox reactions of this molecule. The in situ evaluation of the OTA interaction with DNA using a DNA-electrochemical biosensor is also reported. The oxidation of OTA is an irreversible process proceeds with the transfer of one electron and one proton in a diffusion-controlled mechanism. The diffusion coefficient of OTA was calculated in pH 7 phosphate buffer to be D(O) = 3.65x10(-6) cm2 s(-1). The oxidation of OTA is also pH dependent for electrolytes with pH<7 and involves the formation of a main oxidation product which adsorbs strongly at the GCE surface undergoing reversible oxidation. In alkaline electrolytes OTA undergoes chemical deprotonation, the oxidation involving only the transfer of one electron. The electrochemical dsDNA-biosensor was also used to evaluate the possible interaction between OTA and DNA. The experiments have clearly proven that OTA interacts and binds to dsDNA strands immobilized onto a GCE surface, but no evidence of DNA-damage caused by OTA was obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nile Blue- Chitosan Composite as a new Electrochemical Sensor for Uric Acid on Glassy Carbon Electrode

Nile blue-Chitosan NB-CH as a new type of organic days-organic composite was made using Nile blue and chitosan. The NB-CH composite was made using a 0.005 M solution of Nile blue NB and a 7 solution of chitosan. To do this, a mixture of Nile blue and Chitosan with the ratio of 2:1 was prepared. The electrocatalytic oxidation of uric acid UA has been studied on glassy carbon electrode by NB-CH u...

متن کامل

Voltammetric Detection of Dopamine and Ascorbic Acid Using a Multi-Walled Carbon Nanotubes/Schiff Base Complex of Cobalt-Modified Glassy Carbon Electrode

The surface of the glassy carbon electrode (GCE) is modified with the composite of new Cobalt complex with a tetradentate Schiff base ligand derived from 3-ethoxysalicylaldehyde and 4,5-dimethyl orthophenylenediamine (CoOEtSal) and multi-walled carbon nanotube (MWCNT). The electrochemical oxidation of ascorbic acid (AA) and dopamine (DA) at the modified electrode was studied using the cyclic an...

متن کامل

Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex

A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...

متن کامل

Electrochemical Oxidation of Flavonoids and Interaction with DNA on the Surface of Supramolecular Ionic Liquid Grafted on Graphene Modified Glassy Carbon Electrode

The study of the interaction between DNA and small molecules such as drugs is one of the current general interest and importance. In this paper, the electrochemical investigation of the interaction between some flavonoids such as rutin, quercetin, and hesperidin with dsDNA on the surface of Supramolecular Ionic Liquid grafted on the Graphene Oxide Modified Glassy Carbon Electrode (</s...

متن کامل

Fabrication of Nano Poly Cresol Red over Glassy Carbon Electrode and its Application in Selective Determination of Uric acid in the Presence of Ascorbic Acid

A selective electrochemical method for the determination of uric acid was developed by using nano poly cresol red modified glassy carbon electrode. This new material has been characterized by Scanning Electron Microscopy, cyclic voltammetry and Differential pulse voltammetry. This modified electrode shows excellent electrocatalytic activity towards the oxidation of uric acid in the presence of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 588 2  شماره 

صفحات  -

تاریخ انتشار 2007