Can a quantum nondemolition measurement improve the sensitivity of an atomic magnetometer?

نویسندگان

  • M Auzinsh
  • D Budker
  • D F Kimball
  • S M Rochester
  • J E Stalnaker
  • A O Sushkov
  • V V Yashchuk
چکیده

We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of N atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as N(-3/4); if strongly squeezed probe light is used, the Heisenberg limit of N-1 scaling can be achieved. However, if the measurement time exceeds tau(rel)/N(1/2) in the former case, or tau(rel)/N in the latter, where tau(rel) is the spin relaxation time, the scaling becomes N(-1/2), as for a standard shot-noise-limited magnetometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High bandwidth atomic magnetometery with continuous quantum nondemolition measurements.

We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a fourfold improvement in the measurement bandwidth of the magnetometer using continuous quantum nondemolition measurements. Operating in the scalar mode with a measurement volume of 2 cm3 we achieve magnetic field sensitivity of 22 fT/Hz(1/2) and a bandwidth of 1.9 kHz wit...

متن کامل

Suppression of spin projection noise in broadband atomic magnetometry.

We demonstrate that quantum nondemolition measurement, combined with a suitable parameter estimation procedure, can improve the sensitivity of a broadband atomic magnetometer by reducing uncertainty due to spin projection noise. Furthermore, we provide evidence that real-time quantum feedback control offers robustness to classical uncertainties, including shot-to-shot atom number fluctuations, ...

متن کامل

Squeezed-light optical magnetometry.

We demonstrate a light-shot-noise-limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB. The technique could improve the sensitivity of the most advanced magnetometers and quantum nondemolition measurements of atomic spin ensembles.

متن کامل

Precision measurements of spin interactions with high density atomic vapors

Polarized atomic vapors can be used to detect fields interacting with a spin. Recent advances have extended the sensitivity of atomic magnetometers to a level favorable for fundamental physics research, and in many cases the sensitivity approaches quantum metrology limits. In this thesis, we present a high density atomic K-He comagnetometer, which features suppressed sensitivity to magnetic fie...

متن کامل

Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises

Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 93 17  شماره 

صفحات  -

تاریخ انتشار 2004