Pii: S0141-9382(98)00048-1

نویسندگان

  • A. G. Chakhovskoi
  • C. E. Hunt
  • M. E. Malinowski
چکیده

Gas desorption from field emitter array (FEA) cathode and phosphor screen anode in a flat panel display during lifetime operation can affect cathode electron emission and degrade display performance and uniformity. We have measured the outgassing products from selected FEA-phosphor pairs in an ultrahigh vacuum system equipped with a calibrated quadrople residual gas analyzer. Different low voltage phosphors and blank anodes were studied. A Spindt-type FEA was used as the electron source. A unique carousel was used so the desorption from all these different anodes could be measured without intervening vacuum breaks: this allowed the desorption from the different anodes to be directly compared to each other. Quantitative outgassing rates are given and the implications of the results for the pumping of the flat panel and emission from the FEAs are discussed. q 1999 Published by Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A scalable register file architecture for superscalar processors

A major obstacle in designing superscalar processors is the size and port requirement of the register file. Multiple register files of a scalar processor can be used in a superscalar processor if results are renamed when they are written to the register file. Consequently, a scalable register file architecture can be implemented without performance degradation. Another benefit is that the cycle...

متن کامل

Pii: S0141-9382(00)00030-5

Systematic studies of MBE grown SrS:Cu thin film blue phosphors are reported. It was found that Cu was not oxidized in the as-grown SrS:Cu films. The oxidation and diffusion of Cu during the postgrowth annealing in a H2S atmosphere were identified as the key reasons for the dramatically improved grain size and luminescent properties reported earlier. Experimental evidence of the oxidation state...

متن کامل

Pii: S0141-9382(98)00053-5

Aim: A commonly used method to examine the ability of the visual system to discriminate colours is based on isochromatic plates, such as the Ishihara plates. This article will introduce a computer-based method to determine red–green colour deficiencies based on presenting Ishihara plates using a CRT monitor. Method: The spectral emission of the reflected daylight of the plates was compared with...

متن کامل

Pii: S0141-9382(00)00032-9

A series of charge compensation investigations on SrS:Cu grown by physical vapor phase are reported. In this study, the trivalent ion, Y, was codoped during SrS growth to substitute on the Sr-site. Although similar EL performance to high temperature annealed sputtered samples was obtained using an annealing temperature of 6508C, our results indicated that the thermal quenching in this material ...

متن کامل

Pii: S0141-9382(99)00009-8

The procedure to compute the subjective difference between two input images should be equivalent to a straightforward difference between their perceived versions, hence reliable subjective difference metrics must be founded on a proper perception model. For image distortion evaluation purposes, perception can be considered as a set of signal transforms that successively map the original image i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999