X-ray scattering in full-field digital mammography.

نویسندگان

  • Kirsi Nykänen
  • Samuli Siltanen
چکیده

Effects of x-ray scattering on full-field digital mammography are analyzed with the scattering model of Seibert and Boone [Med. Phys. 15, 567-575 (1988)]. A new method is introduced for the estimation of model parameters from measurements. It is shown that with breasts thinner than a certain threshold, removing the anti-scatter grid leads to an improved contrast-to-noise ratio with a smaller patient dose. A fast approximate algorithm is presented for determining the scattered field in a gridless digital mammogram.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code

Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5...

متن کامل

Scatter correction in digital mammography based on image deconvolution.

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energ...

متن کامل

Effective x-ray attenuation coefficient measurements from two full field digital mammography systems for data calibration applications

BACKGROUND Breast density is a significant breast cancer risk factor. Currently, there is no standard method for measuring this important factor. Work presented here represents an essential component of an ongoing project that seeks to determine the appropriate method for calibrating (standardizing) mammography image data to account for the x-ray image acquisition influences. Longer term goals ...

متن کامل

Linear scanning sensors for medical X-ray imaging

8 The advantages of digital radiography (DR) over screen-fi lm (SF) techniques in medical X-ray imaging are well documented in the literature and unanimously acknowledged by radiologists as well as physicists. For the past decade manufacturers have developed a number of commercial digital X-ray imaging systems covering the full range of radiographic applications. The tight requirements in terms...

متن کامل

Patient doses from screen-film and full-field digital mammography in a population-based screening programme.

The aim of this study was to compare mean glandular dose (MGD) in all full-field digital mammography (FFDM) and screen film mammography (SFM) systems used in a national mammography screening program. MGD from 31 screening units (7 FFDM and 24 SFM), based on an average of 50 women at each screening unit, representing 12 X-ray models (6 FFDM and 6 SFM) from five different manufacturers were calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 2003