Non-invasive Measures of Core Temperature versus Ingestible Thermistor during Exercise in the Heat

نویسندگان

  • DONOVAN L. FOGT
  • ANDREA L. HENNING
  • ADAM S. VENABLE
  • BRIAN K. MCFARLIN
چکیده

The accuracy of core temperature (Tc) thermometry from temporal, tympanic, and oral thermometry devices has been variable during exercise in a hot, humid environment. The purpose of the present study was to cross-validate temporal, two tympanic devices, and oral devices compared to an ingestible thermistor during exercise in a hot, humid environment. Fourteen young, active adults (6 women) completed a graded exercise test until voluntary exhaustion in an environmental chamber (35.5 ± 0.6 °C, 53.9 ± 5.8 % RH). There was no statistical difference in mean temperature between tympanic device 1 and pill-based core temperature (PBTc) measurements across all time points and were positively correlated (0.357; P<0.001). Temperatures of tympanic device 2 were statistically higher than PBTc (37.8 ± 0.7 ºC vs. 37.6 ± 1.0 ºC; respectfully) (P=0.008). At all time points, temperatures for the second tympanic device and PBTc were positively correlated (0.192; P=0.043). Temporal and PBTc values did not differ across time points and were positively correlated (0.262; P=0.005) across all time points. Mean oral temperature was significantly less than mean PBTc across all time points. (37.0 ± 0.4 ºC vs. 37.6 ± 1.0 ºC, respectively) (P<0.001). Across all time points, oral and PBTc were positively correlated (0.262; P=0.010). Tympanic and temporal devices can reflect Tc while exercising in a hot, humid environment. However, care should be taken when selecting the tympanic or temporal measurement device and validation is advised prior to heat illness mitigation in the field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise.

Exercise results in an increase in core body temperature (Tc), which may reduce exercise performance and eventually can lead to the development of heat-related disorders. Therefore, accurate measurement of Tc during exercise is of great importance, especially in athletes who have to perform in challenging ambient conditions. In the current literature a number of methods have been described to m...

متن کامل

Validation of an ingestible temperature data logging and telemetry system during exercise in the heat

Aim: Intestinal temperature telemetry systems are promising monitoring and research tools in athletes. However, the additional equipment that must be carried to continuously record temperature data limits their use to training. The purpose of this study was to assess the validity and reliability of a new gastrointestinal temperature data logging and telemetry system (e-Celsius™) during water ba...

متن کامل

Preventing heat injuries by predicting individualized human core temperature

Heat injury is a problem for the Armed Forces, especially during deployment to localities with very hot and humid climates. Early warning of a rising core body temperature (TC) can help prevent heat injuries. To this end, we developed an algorithm that, given a series of past TC measurements obtained using an ingestible temperature pill, accumulates evidence of a rising TC over time and provide...

متن کامل

Human thermoregulation and measurement of body temperature in exercise and clinical settings.

This review discusses human thermoregulation during exercise and the measurement of body temperature in clinical and exercise settings. The thermoregulatory mechanisms play important roles in maintaining physiological homeostasis during rest and physical exercise. Physical exertion poses a challenge to thermoregulation by causing a substantial increase in metabolic heat production. However, wit...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017