Numerical Simulation of the Field and Frequency Limits for Volume coils in MRI

نویسندگان

  • Bin Xu
  • Ian Gregg
  • Stuart Crozier
  • Feng Liu
چکیده

As signal to noise ratio in magnetic resonance imaging (MRI) improves with increasing static magnetic field strength there is a strong incentive to develop the technology to acquire images at higher fields. While magnet technology has made it possible to generate fields of 10 Tesla and more, limitations of the radio frequency (RF) hardware prevent the acquisition of high quality images over full regions of interest in clinical applications. Since its introduction, the birdcage coil [1] has become a very popular choice for volume imaging and this paper investigates the high frequency limits of several different sizes and designs of birdcage coils. Unloaded coils are simulated using commercial Method of Moments (MoM) software (FEKO [12]) and the capacitances and radii of the conductors are varied within practical limits to determine a maximum frequency of operation for each coil. Results show that practical birdcages are frequency limited to about 400 MHz for a typical head coil (27cm inside diameter, 30cm shield diameter and 25cm length); 128 MHz for a small whole body coil (60cm inside diameter, 64cm shield diameter and 70cm length) and 100 MHz for a large whole body coil (60cm inside diameter, 64cm shield diameter and 100 cm length). These limits are reduced when interactions with the load are taken into account and experience shows that a typical head coil is limited to about 200 MHz in practical experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Dosimetric Assessment of an in Vitro Exposure Setup for Complex Magnetic Field Reproduction at Intermediate Frequencies

In this paper, a numerical study to assess the dosimetry of an in vitro exposure setup at the intermediate frequencies (IF) is presented and validated. The setup is able to reproduce any complex magnetic induction (B) field waveform using a couple of square coils. In our work, actual signals generated by a 1.5 T magnetic resonance imaging (MRI) apparatus were exploited. Firstly, the simulated B...

متن کامل

Simulation of a Box Annealing Unit

In this paper the heating process in a box annealing unit is simulated and the effect of various parameters involved in the process is examined. For this purpose, the full Naiver-Stokes equations along with the standard k- turbulence model are solved in the fluid region using the finite volume approach. In the solid area the conduction heat transfer equation is employed using approporate surfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003