P wave detector with PP rhythm tracking
نویسنده
چکیده
Automatic detection of atrial activity (P waves) in an electrocardiogram (ECG) is a crucial task to diagnose the presence of arrhythmias. The P wave is difficult to detect and most of the approaches in the literature have been evaluated on normal sinus rhythms and rarely considered arrhythmia contexts other than atrial flutter and fibrillation. A novel knowledge-based P wave detector algorithm is presented. It is self-adaptive to the patient and able to deal with certain arrhythmias by tracking the PP rhythm. The detector has been tested on 12 records of the MIT-BIH arrhythmia database containing several ventricular and supra-ventricular arrhythmias. On the overall records, the detector demonstrates Se = 96.60% and Pr = 95.46%; for the normal sinus rhythm, it reaches Se = 97.76% and Pr = 96.80% and, in the case of Mobitz type II, it demonstrates Se = 72.79% and Pr = 99.51%. It also shows good performance for trigeminy and bigeminy, and outperforms some more sophisticated techniques. Although the results emphasize the difficulty of P wave detection in difficult arrhythmias (supra and ventricular tachycardias), it shows that domain knowledge can efficiently support signal processing techniques.
منابع مشابه
P wave detector with PP rhythm tracking: evaluation in different arrhythmia contexts.
Automatic detection of atrial activity (P waves) in an electrocardiogram (ECG) is a crucial task to diagnose the presence of arrhythmias. The P wave is difficult to detect and most of the approaches in the literature have been evaluated on normal sinus rhythms and rarely considered arrhythmia contexts other than atrial flutter and fibrillation. A novel knowledge-based P wave detector algorithm ...
متن کاملCovariance Analysis of a vector tracking GPS receiver based on MMSE multiuser Detection
In high dynamic conditions, using vector tracking loops instead of scalar tracking loops in GPS receivers is proved as an efficient method to compensate the performance. The Minimum Mean Squared Error detector as a multiuser detector is applied in the vector tracking loop for more reliability and efficiency. The Kalman filter does the two tasks of tracking and extracting the navigation data aft...
متن کاملA performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation
PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets. experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the ...
متن کاملHeart rate, arterial stiffness, and wave reflections in paced patients.
Elevated heart rate (HR) and pulse pressure (PP) have a cumulative effect on cardiovascular risk, with the exception of HR >/=100 bpm. How an increase in HR may influence the PP level has never been investigated. In 11 patients with pacemaker monitoring, aortic (pulse-wave analysis) and digital (photoplethysmographic device) blood pressure were measured at 3 different levels of HR, together wit...
متن کاملLow-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking
This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (∼millihertz) gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity 2Δv/c = Δν/ν0, where Δν is ...