Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction—TROFI II trial

نویسندگان

  • Manel Sabaté
  • Stephan Windecker
  • Andres Iñiguez
  • Lisette Okkels-Jensen
  • Angel Cequier
  • Salvatore Brugaletta
  • Sjoerd H. Hofma
  • Lorenz Räber
  • Evald Høi Christiansen
  • Maarten Suttorp
  • Thomas Pilgrim
  • Gerrit Anne van Es
  • Yohei Sotomi
  • Hector M. García-García
  • Yoshinobu Onuma
  • Patrick W. Serruys
چکیده

AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority < 0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Sex-related Impact on Clinical Outcome of Everolimus-eluting Versus Bare-metal Stents in ST-segment Myocardial Infarction. Insights From the EXAMINATION Trial.

INTRODUCTION AND OBJECTIVES The use of second-generation drug-eluting stents compared with bare-metal stents in patients with ST-segment elevation myocardial infarction reduces the rate of major adverse cardiac events. We aimed to evaluate the impact of sex on the performance of everolimus-eluting stents vs bare-metal stents in ST-segment elevation myocardial infarction at 2-year follow-up. M...

متن کامل

Absorb Bioresorbable Vascular Scaffold Versus Everolimus-Eluting Metallic Stent in€ST-Segment Elevation Myocardial Infarction: 1-Year Results of a Propensity Score Matching Comparison

Fro Ba zC OBJECTIVES The purpose of this study was to compare the 1-year outcome between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic stent (EES) in ST-segment elevation myocardial infarction (STEMI) patients. BACKGROUND The Absorb BVS (Abbott Vascular, Santa Clara, California) is a polymeric scaffold approved for treatment of stable coronary lesions. Limited and not ra...

متن کامل

Five-Year Optical Coherence Tomography in Patients With ST-Segment-Elevation Myocardial Infarction Treated With Bare-Metal Versus Everolimus-Eluting Stents.

BACKGROUND The main causes of late (>1 month) stent thrombosis (ST) are stent uncoverage, malapposition, and neoatherosclerosis. First-generation drug-eluting stents were associated with higher rate of late ST compared with bare-metal stents (BMS), especially in patients with ST-segment-elevation myocardial infarction. Second-generation everolimus-eluting stents (EES) have shown similar rate of...

متن کامل

Predictors and clinical implications of stent thrombosis in patients with ST-segment elevation myocardial infarction: Insights from the EXAMINATION trial.

BACKGROUND Few data are available about safety of second generation drug eluting stents in an all-comer ST elevation myocardial infarction (STEMI) population. We sought to investigate the predictors and clinical implications of 1-year stent thrombosis (ST) in patients with STEMI, included in the EXAMINATION trial. METHODS AND RESULTS The EXAMINATION trial is an all-comer prospective, randomiz...