European concerted action on anticoagulation. Quality assessment of the CoaguChek Mini and TAS PT-NC point-of-care whole-blood prothrombin time monitors.

نویسندگان

  • Leon Poller
  • Michelle Keown
  • Nikhil Chauhan
  • Anton M H P van den Besselaar
  • Armando Tripodi
  • Caroline Shiach
  • Jorgen Jespersen
چکیده

BACKGROUND International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the "true" INR. There is therefore a need for local quality assessment (QA) of the two systems. METHODS A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 centers on both point-of-care testing monitors. Subsets of three and five plasmas were selected as QA plasmas and compared with the remaining 55 to assess the relative ability of the systems to characterize performance at the individual centers. The incidence of aberrant results (outliers; >15% deviation from the true INR) was also recorded. The expected incidence with the QA plasmas was calculated and compared. RESULTS On both systems, INR with the common sets of 55 lyophilized plasmas varied considerably between centers. With the TAS PT-NC, subsets of five and three European Concerted Action on Anticoagulation (ECAA) artificially depleted plasmas gave good correlation with the 55 plasmas, but the coumarin plasmas performed less well. With the CoaguChek Mini, correlation was good with sets of five artificially depleted QA plasmas and reasonable with three but was less satisfactory with the coumarin plasmas. Outliers were detected with both types of plasmas on both test systems but with variable success. CONCLUSIONS With the TAS PT-NC, three ECAA artificially depleted lyophilized plasmas provided reliable QA, but five lyophilized coumarin plasmas were required. With the CoaguChek Mini, five artificially depleted plasmas gave reliable QA but coumarin plasmas gave poorer results. ECAA QA plasmas provide a local system for checking INRs obtained with monitors of both types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma...

متن کامل

Evaluation of a Method for International Sensitivity ndex Calibration of Two Point-of-Care Prothrombin Time (PT) Monitoring Systems (CoaguChek Mini and TAS PT-NC) with Fresh Plasmas Based on Whole-Blood Equivalent PT

Background: The International Sensitivity Index (ISI) calibration of whole-blood prothrombin time (PT) monitors for point-of-care testing (POCT) described by Tripodi et al. (Thromb Haemost 1993;70:921–4) has been shown to be dependable but is too complex and demanding. The use of plasma would simplify calibration of whole-blood POCT PT monitors, but important differences may exist between the I...

متن کامل

A National Field Study of Quality Assessment of CoaguChek Point-of-Care Testing Prothrombin Time Monitors

A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...

متن کامل

CoaguChek point-of-care testing prothrombin time monitors.

A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...

متن کامل

Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods.

OBJECTIVE To find out how accurately two point of care test systems--CoaguChek Mini and TAS PT-NC (RapidPointCoag)--display international normalised ratios (INRs). DESIGN Comparison of the INRs from the two systems with a "true" INR on a conventional manual test from the same sample of blood. SETTING 10 European Concerted Action on Anticoagulation centres. PARTICIPANTS 600 patients on lon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2004