Reduction of downtime and improvement of the utility of a conventional radiotherapy simulator

نویسندگان

  • S. P. Sawchuk
  • K. Knibutat
  • L. Moriarity
چکیده

The modifications made to a radiotherapy simulator that improve its functionality and minimize its downtime are described. Functionality was enhanced with some simple effective improvements. Decreasing the frequency and time spent on repairs reduced downtime. These "in-house" improvements were made to a Varian Ximatron simulator at the Tom Baker Cancer Center. Now there is easier access to the field light and optical distance indicator (ODI). Projections of the field light and ODI are much brighter and ODI adjustment is more reproducible. A crosshair was etched onto the clear x-ray exit window to optically overlap with the crosshair of the reticule. Now, the time required to replace a field light is up to seven times faster and the time to realign a reticule is reduced to the order of three times faster. Only one quality control (QC) check is required after these adjustments. Removal of excess heat within the gantry head has eliminated two major problems: (A) the metal rod supporting the mirror assembly for the field light no longer expands and contracts causing a misalignment of the field light projection, and (B) the damage to the bearing in the cooling fan assembly has been eliminated. The simulator is now more functional and these improvements have reduced downtime significantly, making repairs and adjustments much more convenient and efficient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Measurements of Parotid Glands and Spinal Cord in Conventional Treatment of Nasopharyngeal Carcinoma Using RANDO Phantom and Thermoluminescent Dosimeters

Introduction Radiotherapy is regarded as the first treatment of choice for nasopharyngeal carcinoma. Despite the advantages of radiotherapy, patients may suffer from a wide range of side-effects due to the presence of many sensitive normal tissues in these regions. If the absorbed dose exceeds the tolerance level in parotid glands and the spinal cord, myelopathy, Lhermitte's sign and xerostomia...

متن کامل

Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy

Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose.  In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

Comparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...

متن کامل

Simulation of fire stations resources considering the downtime of machines: A case study

Considering the increasing growth of cities, population and urban fabric density, it seems necessary that emergency facilities and services such as fire stations are positioned optimally so that they can fulfill the demands well. The aim of this study is the optimization of equipment use in the fire stations, minimization the time to arrive at the incident through management of referral call to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2003