A Validated specific Stability-indicating RP-HPLC method for Aripiprazole and its related substances
نویسنده
چکیده
A validated specific stability indicating reversed-phase liquid chromatographic method was developed for the quantitative determination of Aripiprazole and its related substances in bulk samples, pharmaceutical dosage forms in presence of degradation products. Forced degradation studies were performed on bulk sample of Aripiprazole as per ICH prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during basic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked with Aripiprazole. Good resolution between the peaks corresponds to impuritiy-1, degradation products from the analyte were achieved on YMC PACK C18 column using the mobile phase consists a mixture of Sodium dihydrogen Orthophosphate dehydrate with1-Hexane sulfonic acid sodium pH adjusted to 3.0 with ortho-phosphoric acid in water and Acetonitrile using a simple linear gradient. The detection was carried out at 215 nm.The stressed test solutions were assayed against the qualified working standard of Aripiprazole and the mass balance in each case was in between to 98.9-100.1% indicating that the developed LC method was stability-indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Aripiprazole at the time of batch release and also during its storage (Long term and accelerated stability).
منابع مشابه
A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل