The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study
نویسندگان
چکیده
BACKGROUND Unexplained coma after critical illness can be multifactorial. We evaluated the diagnostic ability of bedside Optic Nerve Sheath Diameter [ONSD] as a screening test for non-traumatic radiographic cerebral edema. METHODS In a prospective study, mixed medical-surgical intensive care units [ICU] patients with non-traumatic coma [GCS < 9] underwent bedside ultrasonographic ONSD measurements. Non-traumatic radiographic cerebral edema [NTRCE] was defined as > 5 mm midline shift, cisternal, sulcal effacement, or hydrocephalus on CT. RESULTS NTRCE was identified in 31 of 102 patients [30.4 %]. The area under the ROC curve for detecting radiographic edema by ONSD was 0.785 [95 % CI 0.695-0.874, p <0.001]. ONSD diameter of 0.57 cm was found to be the best cutoff threshold with a sensitivity 84 % and specificity 71 %, AUC 0.785 [95 % CI 0.695-0.874, p <0.001]. Using ONSD as a bedside test increased the post-test odds ratio [OR] for NTRCE by 2.89 times [positive likelihood ratio], whereas post-test OR for NTRCE decreased markedly given a negative ONSD test [ONSD measurement less than 0.57 cm]; negative likelihood ratio 0.22. CONCLUSIONS The use of ONSD as a bedside test in patients with non-traumatic coma has diagnostic value in identifying patients with non-traumatic radiographic cerebral edema.
منابع مشابه
Association between optic nerve sheath diameter and mortality in patients with severe traumatic brain injury.
PURPOSE Increased intracranial pressure (ICP) is associated with worse outcomes following traumatic brain injury (TBI). Studies have confirmed that ICP is correlated with optic nerve sheath diameter (ONSD) on ultrasound. The aim of our study was to assess the independent relationship between ONSD measured using CT and mortality in a population of patients admitted with severe TBI. METHODS We ...
متن کاملDan Benhamou Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury
T. Geeraerts (!) · Y. Launey · L. Martin · J. Pottecher · B. Vigué · J. Duranteau · D. Benhamou University of Paris-Sud, Department of Anesthesiology and Critical Care Medicine, Hospital of Bicêtre, Assistance Publique-Hôpitaux de Paris (AP-HP), Faculty of Medicine, Le Kremlin Bicêtre, 94275 Paris, France e-mail: [email protected] Tel.: +33-1-45213429 Fax: +33-1-45212875 Abstract Obj...
متن کاملOptic nerve ultrasound for the detection of raised intracranial pressure.
BACKGROUND Optic nerve ultrasonography (ONUS) may help identify raised intracranial pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification of intracranial hypertension has not been established, with some clinical studies suggesting a higher cut-off than may be expected on the basis of prior laboratory investigation. OBJECTIVE To validate ONUS performed b...
متن کاملEstimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients
INTRODUCTION The aim of this study was to evaluate the prognostic value of optic nerve sheath diameter (ONSD) measured on the initial brain computed tomography (CT) scan for intensive care unit (ICU) mortality in severe traumatic brain injury (TBI) patients. METHODS A prospective observational study of all severe TBI patients admitted to a neurosurgical ICU (over a 10-month period). Demograph...
متن کاملمقایسه دریافت خوابآور به صورت بلوس و انفوزیون در بروز پنومونی ناشی از تهویه مکانیکی در بیماران ترومایی دارای لوله تراشه در ICU
Introduction: Ventilator-associated pneumonia (VAP) is one of the most important complications of mechanical ventilation and cause of mortality in traumatic patients under mechanical ventilation admitted in the ICU (intensive care unit). The aim of current study was comparing sedationreceived as bolus and infusion at incidence of VAP in intubated traumatic patients in the ICU. Methods:...