An electrochemical time-of-flight technique with galvanostatic generation and potentiometric sensing
نویسندگان
چکیده
A variation of an electrochemical time-of-flight (ETOF) technique is described and illustrated with the test cases involving electrochemically generated Ag and H ions in aqueous solutions of different viscosity and ionic strength. Similar to the earlier ETOF methods, the new ETOF technique also relies on photolithographically fabricated microelectrode devices. It uses a constant current (rather than potentiostatic) mode of generation of redox species and, unlike earlier approaches, it uses potentiometric (rather than amperometric) monitoring of the rates of their diffusion to the sensor microelectrode. The unknown D -values can be obtained by direct comparison between the experimentally obtained and digitally simulated E vs t transients. Digital simulations were based on simple hemi-cylindrical diffusion between the microband generator modeled as a hemi-cylinder and sensor microband electrode assumed to be infinitesimally small. This model approximates well the experimental results as long as the spacing between the two microband electrodes is approximately equal to or greater than twice their width. Discrepancies between theory and experiment may also arise due to the double-layer charging of the sensor j solution interface, and migration effects. # 2003 Elsevier Science B.V. All rights reserved.
منابع مشابه
Measurements of the capacitance and the response time of solid-state potentiometric sensors by an electrochemical time-of-flight method
A micro-electrochemical time-of-flight technique relying on galvanostatic ion generation and potentiometric sensing (P-ETOF) has been developed in order to characterize dynamic properties of solid-state potentiometric sensors and to measure their capacitance. Lithographically-fabricated generator-sensor devices featuring 10 lm-wide micro-electrodes spaced by 20– 50 lm are used in either an open...
متن کاملBinder-free copper hexacyanoferrate electrode prepared by pulse galvanostatic electrochemical deposition for aqueous-based Al-ion batteries
Copper hexacyanoferrate (CuHCF) nanoparticles with tunnel-like Prussian blue structure were deposited on graphite substrate via pulse galvanostatic electrochemical deposition at 25 mA cm-2 with both on-time and off-time periods of 0.1 s, which presented the ability to intercalation/de-intercalation of Al ions reversibly in aqueous solution. The crystal structure of the as-prepared CuHCF f...
متن کاملLabel-free electrochemical biosensors for food and drug application
In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...
متن کاملLabel-free electrochemical biosensors for food and drug application
In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...
متن کاملSynthesis and electrochemical studies on Cu-TiO2 thin films deposited by spray pyrolysis technique for sensing Uric acid
In this study, we report an effective uric acid (UA) electrochemical biosensor using Cu-TiO2 electrode. UA is a biomedical compound that plays a vital role in human metabolism. The abnormal level of UA leads to several diseases. TiO2 and Cu-TiO2 with various concentrations were deposited on glass substrates by spray pyrolysis technique. The structural study show...
متن کامل