The Effect of Interimplant Distance on Peri-implant Bone and Soft Tissue Dimensional Changes: A Nonrandomized, Prospective, 2-Year Follow-up Study.

نویسندگان

  • Theofilos Koutouzis
  • Rodrigo Neiva
  • David Lipton
  • Tord Lundgren
چکیده

PURPOSE To prospectively evaluate peri-implant bone and soft tissue dimension changes around adjacent implants placed at different horizontal interimplant distances. MATERIALS AND METHODS Thirty partially edentulous patients, who underwent rehabilitation with two adjacent implant-supported crowns as part of their treatment plan, were assigned to three groups based on their prosthetic needs. Patients in group A (10 patients, 20 implants) were to have two implants placed at a 2-mm interimplant distance, patients in group B (10 patients, 20 implants) were to have two implants placed at a 3-mm interimplant distance, and patients in group C (10 patients, 20 implants) were to have two implants placed at an interimplant distance of > 4 mm according to their prosthetic needs. All patients received single-crown restorations after 3 months. Clinical examinations were performed at the time of crown placement (T3), and 6 months (T6), 12 months (T12), and 24 months (T24) after implant placement. Peri-implant bone levels were assessed radiographically at the time of implant placement (T0), and at T3, T12, and T24. RESULTS One patient from group C did not return for follow-up examinations after implant placement. The mean (± standard deviation) horizontal interimplant distance was 1.97 ± 0.44 mm for implants in group A, 3.12 ± 0.15 mm for implants in group B, and 5.3 ± 0.64 mm for implants in group C. For group A, the mean marginal bone loss was 0.29 ± 0.51 mm at the T0-T3 interval, 0.31 ± 0.36 mm at the T0-T12 interval, and 0.27 ± 0.33 mm at the T0-T24 interval. For group B, the mean marginal bone loss was 0.16 ± 0.29 mm at the T0-T3 interval, 0.20 ± 0.28 mm at the T0-T12 interval, and 0.23 ± 0.28 mm at the T0-T24 interval. For group C, the mean marginal bone loss was 0.51 ± 0.84 mm at the T0-T3 interval, 0.45 ± 0.72 mm at the T0-T12 interval, and 0.44 ± 0.74 mm at the T0-T24 interval. For group A, the mean midproximal bone loss was 0.33 ± 0.50 mm at the T0-T3 interval, 0.45 ± 0.35 mm at the T0-T12 interval, and 0.40 ± 0.32 mm at the T0-T24 interval. For group B, the mean midproximal loss was 0.31 ± 0.37 mm at the T0-T3 interval, 0.32 ± 0.39 mm at the T0-T12 interval, and 0.33 ± 0.42 mm at the T0-T24 interval. For group C, the mean midproximal bone loss was 0.40 ± 0.44 mm at the T0-T3 interval and 0.41 ± 0.50 mm at both the T0-T12 and T0-T24 intervals. There were no statistically significant differences in marginal and midproximal bone crest loss between the different groups at any time point. CONCLUSION The study failed to support the hypothesis that horizontal interimplant distance has an effect on peri-implant bone and soft tissue dimension changes for implants with internal conical implant-abutment interface connection and platform-switching characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The dental implant surface that elicits a true connective tissue attachment

Interimplant papillae are critical to achieving esthetic implant-supported restorations in the maxillary esthetic zone. Stable papillary anatomy, however, depends upon a stable volume of underlying crestal bone for support. Multiple studies have documented a critical interimplant distance of 3 mm, under which crestal bone resorption occurs. The current preclinical proof-of-principle canine stud...

متن کامل

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Mucosa Thickness and Peri-implant Crestal Bone Stability: A Clinical and Histologic Prospective Cohort Trial.

PURPOSE To correlate soft tissue thickness and peri-implant bone remodeling of platform-switching implants. MATERIALS AND METHODS This comparative prospective trial evaluated, for up to 3 years after implant loading, the influence of soft tissue thickness on changes in peri-implant marginal hard tissue levels. Any patient who was partially edentate in the mandible and required at least two ad...

متن کامل

Effects of a new implant abutment design on peri-implant soft tissues.

The purpose of this study was to assess the effects of a modified implant abutment design on peri-implant soft and hard tissues in dogs. Three months after extraction of mandibular premolar teeth, 3 dental implants were placed in each side of the jaw using a 1-stage approach. Implants on one side of the mandible received standard abutments (control), and implants on the contralateral side recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2015