Detection of Legionella Pneumophila in Water and Biofilm Samples by Culture and Molecular Methods from Man-made Systems in São Paulo - Brazil

نویسندگان

  • Fábio R. S. Carvalho
  • Annette S. Foronda
  • Vivian H. Pellizari
چکیده

Legionella pneumophila is a pathogenic bacteria associated to aquatic habitat of natural and artificial environments. Clinical cases of legionellosis have been reported in Brazil but there is a lack of information about the incidence and concentration of this bacterium in environmental sources. Thus, the present study was designed to evaluate the occurrence of legionellae in São Paulo city, Brazil, using different methods of detection and identification. Sixty-seven water and biofilm samples from natural reservoirs and man-made systems were collected and analyzed for the presence of Legionella spp by culturing onto a selective medium, coculture in axenic free-living amoebae and direct fluorescent antibody (DFA) assay. Results showed that freshwater of reservoirs did not contain legionellae, Legionella pneumophila was isolated from man-made systems, with predominance of Legionella pneumophila serogroup 1 strains. Although there was no statistical difference among the proposed detection methods, the plate culture method yielded a higher number of L. pneumophila positive samples, followed by amoebic coculture procedure and direct fluorescent antibody assay. Results of PCR and sequencing reactions revealed that application of macrophage infectivity potentiator gene as a molecular marker was an important tool for the identification of environmental isolates of L. pneumophila. The agreement among the three detection methods-when all methods yielded similar resultsand the prevalence of a single Legionella species in the sampled man-made systems could suggest that the occurrence of this bacterium had been influenced by the higher concentration of metallic ions dissociated in water of those systems than in natural reservoirs. Thus, the results of this study revealed that the water of man-made systems in Sao Paulo may serve as a reservoir for L. pneumophila and other microorganism, including free-living protozoans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

فراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان

Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They wer...

متن کامل

Molecular evidence for the ubiquitous presence of Legionella species in Dutch tap water installations.

Our aim was to investigate the occurrence and identity of Legionella spp. in Dutch tap water installations using culture, real-time PCR and sequence analysis. The PCR assays used were a 16S rRNA gene based PCR with both a Legionella species specific probe and a L. pneumophila specific probe and a L. pneumophila-specific PCR based on the sequence of the mip gene. A total of 357 water samples fro...

متن کامل

شناسایی لژیونلا پنوموفیلا از نمونه‌های خلط بیماران مبتلا به پنومونی با روش کشت، ایمنوفلورسانس مستقیم و PCR

Abstract Background: Community acquired pneumonia (CAP) is the main cause of mortality and morbidity world wide. Legionella pneumophila is identified as the fourth agent that causes CAP. The aim of this study was to define the prevalence of L. pneumophila among hospitalized children by culture, direct immune-fluorescence, (DFA) and PCR. Methods: In this study 210 sputum samples were collect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007