[Distribution of inhaled aerosol using nasal nebulizer].

نویسندگان

  • T Ogoshi
  • N Usui
چکیده

In this paper, we examined distribution and deposition of inhaled 99mTc aerosols in human respiratory tract, nebulization equipment and expired aerosols. Jet nebulizers were used and aerosols were inhaled through the nose. Results were as follows: 1. On normal breathing, deposition rate of human respiratory tracts in normal subjects were 22% of total dosage and there was no difference from sinusitis group. But, deposition rate of nasal cavity was higher than in sinusitis group normal in group. 2. In normal subjects, there was no influence of breathing pattern to deposition rate of nasal cavity. 3. Distribution of the lung was significantly increased on deep breathing in both groups. 4. Residual volume of nebulizer bottle were about 50% of total dosage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of radio-labeled aerosol delivery via a variable-flow infant CPAP system.

BACKGROUND Nasal CPAP is widely used in neonatal ICUs. Aerosolized medications such as inhaled steroids and β agonists are commonly administered in-line through nasal CPAP, especially to infants with bronchopulmonary dysplasia. We hypothesized that aerosol delivery to the lungs via variable-flow nasal CPAP in an in vitro model would be unreliable, and that the delivery would depend on the posit...

متن کامل

In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns.

BACKGROUND An aerosol of budesonide inhalation suspension is delivered when used with various jet-nebulizer/compressor combinations. The constant introduction of new nebulizer/compressor combinations raises the question of whether the performance of these match the performance of existing devices. The aim of this study was to determine in vitro the inhaled mass and aerosol characteristics of bu...

متن کامل

Comparison of drug delivery from conventional versus "Venturi" nebulizers.

Attempts to improve drug delivery from conventional jet nebulizers have included the use of storage systems to reduce drug wastage during exhalation. Venturi nebulizers enhance drug delivery during inhalation, reducing treatment times and drug wastage. This study investigated the effect of age on inhaled dose from a conventional jet nebulizer (Acorn) used both with and without a storage chamber...

متن کامل

Influence of nebulizer type with different pediatric aerosol masks on drug deposition in a model of a spontaneously breathing small child.

BACKGROUND The performance of nebulizers varies with the design type as well as the breathing patterns of various age groups. The present study quantified aerosol delivery using spontaneously breathing parameters of a small child (2-4 years) by a lung simulator to determine the influence of nebulizer type, actuation mechanisms, and pediatric aerosol masks. METHODS Three types of nebulizer (c...

متن کامل

Testing of nebulizers for delivering magnesium sulfate to pediatric asthma patients in the emergency department.

BACKGROUND As the use of intravenous magnesium sulfate (MgSO(4)) for the treatment of refractory asthma is becoming more common, the incidence of MgSO(4)-related systemic hypotension is also rising. One option is to deliver MgSO(4) via aerosol, but compared to most inhaled medications, which are active in the microgram dose range, the MgSO(4) dose requirement is in the milligram range. This, al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Jibiinkoka Gakkai kaiho

دوره 94 1  شماره 

صفحات  -

تاریخ انتشار 1991