Fracture morphology and fracture management.

نویسنده

  • Kenneth A Johnson
چکیده

doi:10.3415/VCOT-12-12-0154 Our first issue of VCOT for this year contains several papers pertaining to the study of fracture morphology, and the stabilization of fractures with bone plates (1-3). In addition, Herten and colleagues describe the characterization of mesenchymal stem cells isolated from bone marrow by a point-of-care device; these cells had osteogenic potential that could be expected to contribute to the repair of fractures and osseous defects (4). Stability of conventional bone plate fixation of fractures relies on friction between the screw head, the plate and the underlying bone. Conventional plates need to be accurately contoured to exactly match the surface topography of the bone underlying the plate, so that the plate makes good contact with the bone. If the plate contouring is imprecise, then final tightening of the screws can result in translation of the bone fragments and loss of reduction at the fracture site. By contrast, locking bone plates rely on a rigid interaction between the screw head and the hole in the plate. Accurate plate contouring is not necessary because direct contact of the plate with the underlying bone is not required. Apart from the saving in intra-operative time that is normally required for plate contouring, this feature of locking plate fixation might result in less disturbance of bone blood supply. Several different mechanisms have been developed to produce a rigid, locking interaction between the screw and the plate for locking plate fixation. One of the earliest was a threaded locking nut connecting the bone screw to the plate in the Polish technique of Zespol osteosynthesis (5). The Zespol plate can be applied as an internal or an external fixator. A more popular design is one with external threads on the screw head that engage a threaded round hole in the plate, such as that found in the No-Contact Plate, and the Locking Compression Plate® (6, 7). Another recent innovation is a Morse-type conical coupling, incorporated into the Fixin plate (8). In this issue of the Journal is a report about a clinical and radiographic study of canine appendicular fractures stabilized with locking plates that utilize the conical coupling system (2). It was found that 89% of fractures reached clinical union without complications. Fixation failure was mainly due to plate bending and breakage. In the case of imperfectly reduced fractures, both conventional and locking plates function as a buttress plate, and are subject to cyclic bending loads in the region of the fracture gap, resulting in plate bending or plate fatigue and breakage. One limitation of the Fixin plate is that the round hole, conical coupling design of the plate does not allow generation of static interfragmentary compression in two-piece diaphyseal fractures. The presence of small fracture gaps, even those less than 1 mm, can eliminate load sharing between the plate and bone, and increase the risk of fatigue failure of the plate. Therefore when buttress function is anticipated, then the use of a thicker plate, double plating, or plate rod fixation should be considered; also application of plates with an empty screw hole in the region of the fracture should be avoided. Some of these strategies were successfully employed in the cases described by Nicetto and colleagues (2). The novel use of a locking bone plate in the successful treatment of a tibial facture in young grey seal is also described in a case report, and highlights the challenges of managing complications, rehabilitation and follow-up fracture evaluation in a wild animal (3).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical treatment and a unique management of rostral mandibular fracture with cerclage wire in a horse

A 3-year-old Arabian colt was presented for a major gingiva wound at the right rostral part of mandible. After clinical assessments, rostral mandibular fracture was determined. Stabilization of fractured region was achieved via cerclage wire application under general anesthesia. Fixation wires were left in place for 6 weeks. A 3 -month follow up revealed complete fracture healing. The purpose o...

متن کامل

The Effect of Temperature on the Fracture Surface Morphology and Ductility of La55Al25Ni5Cu10Co5 BMG

In this research, the effect of temperature on the mean size of fracture surface features, as well as the relation between fracture surface morphologies and ductility of a La-based BMG as a relatively brittle alloy, was systematically investigated. After producing the alloy, three-point bending experiments, over a wide range of temperatures, were conducted on the samples; then the fracture surf...

متن کامل

Recurrent hip fracture prevention with osteoporosis management

 Abstract Background: Osteoporosis is a major public health threat, and hip fracture is a serious consequence of osteoporosis. Apatient with an osteoporosis-related hip fracture has an increased risk for a second hip fracture. The effect of osteoporosis management on the risk of recurrent hip fracture was evaluated in this study. Methods: 58 hip fracture patients older than 50yr and BMD < 2.5 w...

متن کامل

Management of Hip Fractures in Lateral Position without a Fracture Table

Background:  Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays’ dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view. ...

متن کامل

Apical Force Application in the Management of Dentoalveolar Fractures: Indications, Procedure and Limitations

Dentoalveolar fracture is defined as a fracture in the bone surrounding the teeth without any extension to the basal bones of the maxilla or mandible (1). As for other parts of the facial skeleton, the treatment strategy for dentoalveolar fractures consists of fracture reduction, fixation and immobilization (2); however, some dentoalveolar fractures are difficult to treat. In some dentoalveola...

متن کامل

Management of a bilateral mandibular fracture in a single-humped camel

In the present case report, the comprehensive management of a bilateral mandibular fracture in a single-humped camel including pre-, peri- and post-operative cares is described. A one-year-old camel with the overhanging of the rostral part of the lower jaw which occurred seven days ago was presented. After clinical and radiographic examinations, a bilateral mandibular fracture at the caudal par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary and comparative orthopaedics and traumatology : V.C.O.T

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2013