Some Experiments with Chromium Compounds as Fixers for Electron Microscopy

نویسندگان

  • Frank N. Low
  • James A. Freeman
چکیده

In the course of experimentation with various tissue fixations other than Os04 it was noticed that mixtures containing chromium compounds showed considerable promise. Therefore the fixation characteristics of three such compounds, CrC13, K2Cr~07 and Cr08 (the anhydride of H2Cr04), were systematically investigated. Although the action of all three was essentially similar, CrO~ proved to be the m o s t satisfactory and was used exclusively in subsequent experiments. Its concentration was varied from 1 to 6 per cent. It was tried in combination with formaldehyde, the Concentration of which was varied from 2 to 32 per cent. Sodium chloride, in concentrations never exceeding 3.4 per cent, was used t o control tonicity in many experiments. A number of standard buffers were mixed with the solutions without noticeable profit. The fluid finally adopted as the most satisfactory was an aqueous solution containing 3 per cent chromic oxide (CrOa), 4 per cent formaldehyde (I-ICHO) and 0.85 per cent sodium chloride (NaC1). The ptI of this mixture was about 3.2. The fixation time was varied from 5~ to 17 hours, but after several hours fixation * Aided bygrants from the Public Health Service (H-1663) and The Lilly Research Laboratories. ~t Public Health Training Fellow (HTS-sill). the tissue resembled a metal-shadowed preparation, (apparently due t o gradual deposition of chromium) and so it was decided that a short fixation of k~ :to ~ hour was best. Washing for ~ hour in distilled water immediately after:fixation produced "cleaner" preparations. Since cells rich in endoplasmi¢ reticulum such as those of the exocrine pancreas responded most favorably t o this type of fixation, these were adopted as test ob-jeets in developing the procedures, Occa. sionally the somewhat less basophilic parotid cells were also used. After methacrylate embedding the tissue was light yellow or brown with a darker center and the dark areas deep in the tissue ustmlly represented areas of better fixation. The tissue was brittle and hard, but with care could be sectioned in silver ribbons with a Porter-Blum micro-tome. Despite the common presence of fine chatter good sectiOns Were obtained from almost every block. The general appearance of pancreatic acinar cells fixed by this method is: fllns. trated in Figs. 1 to 4. The spaces within the endoplasmic reticulum appear less dense and alternate throughout most of the cytoplasm with darker bands representing : the cytoplasmic matrix. The apparently linear organization of: the cytoplasm is …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Nano-Adsorbents for the Removal of Chromium (III) and Mercury (II) from Aqueous Solutions

Polyvinyl alcohol/ glycerin- magnetic iron oxide nanoparticles (PVAGLPs) have been synthesized successfully by hydrothermal method. The as-prepared samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectra (FTIR). The adsorbed activities of the polyvinyl alcohol/ glycerin- magnetic iron oxide nano particles (PVAGLPs) were ca...

متن کامل

A Transmission Electron-Microscopy Study of RF-Magnetron-Sputtered and DC-Magnetron-Sputtered Thin-Film Chromium and Chromium Platinum Coatings

Microstructural features of sputtered chromium and chromium-50 wt. % platinum thin films on carbon substrates are presented. Films produced by rf sputtering and dc magnetron sputtering are compared using analytical electron microscopy techniques. All rf-sputtered films are uniform in chemistry and thickness and are amorphous. The chromium film became crystalline with a grain size ofless than 10...

متن کامل

Plasma spraying and characterization of chromium carbide – nickel chromium coatings

Chromium carbide – nickel chromium powder Cr3C2-25wt.NiCr was plasma sprayed by a water-stabilized system WSP®. A series of experiments with variable feeding distance was carried out. Basic characterization of coatings was done by XRD, SEM and light microscopy plus image analysis. Microhardness was measured on polished cross sections. The main focus of investigation was on resistances against w...

متن کامل

An analytical procedure for determining chromium in samples of airborne dust.

A method is described for assessing occupational exposures to chromium aerosols; it involves four procedures. The first, proton induced X-ray emission (PIXE), measures the total chromium. The second, electron spectroscopy for chemical analysis (ESCA), measures the oxidation state of the particle surfaces, and the third, which uses sym-diphenylcarbazide (DPQ, measures the proportion of water-sol...

متن کامل

TIG Surface Alloying of Ti-6Al-4V with Nitrogen and Chromium for Improved Tribological Properties

Due to special properties such as low density, high strength and high corrosion resistance Ti-6Al-4V alloy has been used extensively in various industries, especially in the aerospace aspects. However the major problem of this alloy is its poor tribological properties under relatively high loads. In the present study, in order to improve the tribological properties of mentioned alloy, chromium ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Biophysical and Biochemical Cytology

دوره 2  شماره 

صفحات  -

تاریخ انتشار 1956