Measurement of extravascular lung water using the single indicator method in patients: research and potential clinical value.

نویسندگان

  • Lisa M Brown
  • Kathleen D Liu
  • Michael A Matthay
چکیده

Extravascular lung water includes all of the fluid within the lung but outside of the vasculature. Lung water increases as a result of increased hydrostatic vascular pressure or from an increase in lung endothelial and epithelial permeability or both. Experimentally, extravascular lung water has been measured gravimetrically. Clinically, the chest radiograph is used to determine whether extravascular lung water is present but is an insensitive instrument for determining the quantity of lung water. Bedside measurement of extravascular lung water in patients is now possible using a single indicator thermodilution method. This review critically evaluates the experimental and clinical evidence supporting the potential value of measuring extravascular lung water in patients using the single indicator method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three methods of extravascular lung water volume measurement in patients after cardiac surgery

INTRODUCTION Measurement of extravascular lung water (EVLW) by using the lithium-thermal (Li-thermal) and single-thermal indicator dilution methods was compared with the indocyanine green-thermal (ICG-thermal) method in humans. METHODS Single-center observational study involving patients undergoing cardiac surgery with cardiopulmonary bypass. Paired measurements were taken 1, 2, 4, and 6 hour...

متن کامل

Measurement of extravascular lung water in patients with pulmonary edema.

MEASUREMENT OF EXTRAVASCULAR lung water has been a topic of major interest for more than two decades (1, 5, 19). In the recent article by Effros et al. (2), they provide a review of current and past efforts to measure extravascular lung water with thermal and osmotic dilution methods. The authors discuss several of the limitations of these methods, including problems related to early recirculat...

متن کامل

Extravascular Lung Water and Acute Lung Injury

Acute lung injury carries a high burden of morbidity and mortality and is characterised by nonhydrostatic pulmonary oedema. The aim of this paper is to highlight the role of accurate quantification of extravascular lung water in diagnosis, management, and prognosis in "acute lung injury" and "acute respiratory distress syndrome". Several studies have verified the accuracy of both the single and...

متن کامل

Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study

INTRODUCTION Gravimetric validation of single-indicator extravascular lung water (EVLW) and normal EVLW values has not been well studied in humans thus far. The aims of this study were (1) to validate the accuracy of EVLW measurement by single transpulmonary thermodilution with postmortem lung weight measurement in humans and (2) to define the statistically normal EVLW values. METHODS We eval...

متن کامل

Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements.

The thermal dye double indicator dilution technique for estimating lung water was compared with gravimetric analyses in nine human subjects who were organ donors. As observed in animal studies, the thermal dye measurement of extravascular thermal volume (EVTV) consistently overestimated gravimetric extravascular lung water (EVLW), the mean (SEM) difference being 3.43 (0.59) ml/kg. In eight of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Lung cellular and molecular physiology

دوره 297 4  شماره 

صفحات  -

تاریخ انتشار 2009