Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.

نویسندگان

  • S A Smith
  • A E Russell
  • M J West
  • J Chalmers
چکیده

Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subjects and on exercise in 11 subjects. Cardiac output values obtained with impedance cardiography were significantly correlated with those measured by the indirect Fick method, although there was a wide scatter with over 73% of the readings lying outside the limits defined by the line of identity +/- 20%. This correlation was greatly reduced when stroke volume index was used instead of cardiac output. Indirect Fick results were linearly related to oxygen uptake both at rest and on exercise, while impedance cardiography results did not correlate with oxygen uptake. Impedance cardiography gave consistently lower results for cardiac output than indirect Fick at all levels of exercise. Both machines were easy to use and produced acceptable mean (SE) coefficients of variation (BoMed NCCOM3 7.7 (1.0)%, Gould 9000 IV 10.6 (1.4)%). Further validation is required before either of these machines can be recommended as an alternative to invasive monitoring in clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.

The accuracy and reproducibility of indirect measurement of cardiac output at rest by the carbon dioxide rebreathing (indirect Fick) method with an automated respiratory analysis system (Gould 9000IV) were compared with simultaneous measurements made in duplicate by dye dilution and thermodilution in 25 patients having cardiac catheterisation studies. Measurements of cardiac output by the carbo...

متن کامل

What technique should I use to measure cardiac output?

PURPOSE OF REVIEW Several less invasive cardiac output monitoring techniques are now commercially available and have the potential to replace the pulmonary artery catheter under certain clinical circumstances. The aim of this review is to give a synopsis of the currently available cardiac output measurement methods. This information should help in selecting the appropriate technique in a partic...

متن کامل

Accuracy and Reliability of Non-invasive Cardiac Output: The Future in Cardiology?

A new generation of non-invasive cardiac output monitors provides an alternative to using conventional invasive methods such as thermodilution and direct Fick. The Bioz.com measures changes in thoracic electrical bioimpedance (TEB) of the descending aorta. The Innocor uses the principle of inert gas rebreathing. Simultaneous TEB and thermodilution cardiac output measurements were taken from 27 ...

متن کامل

Noninvasive monitoring cardiac output using partial CO(2) rebreathing.

This article reviews use of partial carbon dioxide rebreathing devices to determine cardiac output and their application for hemodynamic monitoring in the ICU and operating room. The primary focus is on the NICO monitoring device. Compared with conventional cardiac output methods, these techniques are noninvasive, easily automated, and provide real-time and continuous cardiac output monitoring....

متن کامل

Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study

INTRODUCTION New technology using partial carbon dioxide rebreathing has been developed to measure cardiac output. Because rebreathing increases respiratory effort, we investigated whether a newly developed system with 35 s rebreathing causes a lesser increase in respiratory effort under partial ventilatory support than does the conventional system with 50 s rebreathing. We also investigated wh...