Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study.

نویسندگان

  • T Apivatthakakul
  • S Patiyasikan
  • S Luevitoonvechkit
چکیده

Several recent reports have described the minimally invasive plate osteosynthesis (MIPO) technique in the treatment of humeral shaft fractures by the anterior approach. The purpose of this study is to identify the danger zone for locking screw placement to avoid musculocutaneous nerve injury in the anterior compartment and radial nerve injury in the posterior compartment of the humerus relative to the humeral length. Eighteen arms of fresh cadavers were fixed with 10-hole locking compression plate (LCP) by anterior approach using the MIPO technique. Two locking screws on each end were fixed by the open technique; the rest of the screws were inserted percutaneously. The arms were dissected both anterior and posterior to identify musculocutaneous and radial nerve injuries. Humeral length with a simple palpable bony landmark was measured from the posterior tip of the acromion process to the lateral epicondyle. Damage or direct contact of the locking screws to the musculocutaneous or radial nerve was recorded, and the distance between the screws and the radial nerve was measured. The average humeral length was 29.71cm (99% confidence interval (CI): 28.54-30.86cm). The danger zone for the musculocutaneous nerve averaged 18.37% (99% CI: 17.06-19.60) to 42.67% (99% CI: 42.33-43.03) of the humeral length from the lateral epicondyle. The danger zone for the radial nerve averaged 36.35% (99% CI: 35.81-37.07) to 59.20% (99% CI: 59.00-59.46) of the humeral length, and the most dangerous screws that penetrated or touched the radial nerve lay 47.22% (99% CI: 45.27-49.17) to 53.21% (99% CI: 51.16-55.33) of the humeral length from the lateral epicondyle. An anteroposterior locking screw placed percutaneously endangered the musculocutaneous and radial nerves. From this cadaveric study, the danger zone for the musculocutaneous and radial nerves could be determined as a percentage of the humeral length. Since the zone with radial nerve injuries shows a large variation, this procedure should only be done by experienced surgeons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report.

Minimally Invasive Plate Osteosynthesis (MIPO) has gained popularity with satisfactory clinical outcomes in the treatment of long bone fractures. MIPO for humeral shaft fractures, however, could be a surgically dangerous procedure because of the risk of radial nerve injury. An anatomical study was performed to evaluate the feasibility of MIPO for the humeral shaft fractures, and to study the re...

متن کامل

Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus.

Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients with acute displacement involving proximal and middle third humeral shaft fra...

متن کامل

Comparison of minimally invasive plate osteosynthesis and conventional plate osteosynthesis for humeral shaft fracture

BACKGROUND The objective of this meta-analysis was to compare the efficacy and safety of minimally invasive plate osteosynthesis (MIPO) and conventional plate osteosynthesis (CPO) for humeral shaft fracture. METHODS Potential academic articles were identified from the Cochrane Library, Medline (1966-2016.3), PubMed (1966-2016.3), Embase (1980-2016.3), and ScienceDirect (1966-2016.3). Gray stu...

متن کامل

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis

BACKGROUND In this study, we performed a meta-analysis to identify whether minimally invasive plate osteosynthesis (MIPO) was superior to conventional fixation techniques (CFT) for treating humeral shaft fractures. METHODS A systematic literature search was conducted up to February 2016 in ScienceDirect, Springer, MEDLINE, and PubMed databases for relevant papers that compared the outcomes of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2010