Three-dimensional endoluminal CT colonography (virtual colonoscopy): comparison of three commercially available systems.

نویسنده

  • Perry J Pickhardt
چکیده

OBJECTIVE The purposes of this study were to directly compare 3D endoluminal volume rendering and navigational capabilities of three different CT colonography systems and to assess feasibility of 3D evaluation for primary polyp detection. MATERIALS AND METHODS Closely matched endoluminal images from three CT colonography software systems (Navigator, Vitrea 2, and V3D-Colon) and optical colonoscopy were obtained of eight pathologically proven colorectal polyps. All images were then reviewed by 25 physicians (12 radiologists and 13 gastroenterologists) who were not familiar with the three systems. For each polyp, the images yielded by the three systems were rated according to polyp conspicuity, 3D effect (depth), subjective quality, and likeness to optical colonoscopy. For comparison of endoluminal navigation capability, automated or semiautomated flight from rectum to cecum and cecum to rectum was attempted in 10 cases (20 flights) in which a continuous colonic air column could be identified on the 2D images. Additional 3D features were also compared. RESULTS For polyp conspicuity, 3D effect, and likeness to optical colonoscopy, the V3D-Colon system was favored in 92.0% (184/200), 92.5% (185/200), and 92.5% (185/200) of responses, respectively (p < 0.001). For the same categories, the Navigator system ranked second in 73.0%, 74.0%, and 75.0% of cases, and the Vitrea 2 system ranked last in 79.0%, 77.5%, and 76.0% of cases, respectively. Automated or semiautomated navigation was successful in eight (40%) of 20 flights with Vitrea 2, in nine (45%) of 20 flights with Navigator, and in 20 (100%) of 20 flights with V3D-Colon (p < 0.001). The V3D-Colon system also had more navigational features than the other two systems. CONCLUSION Pronounced subjective and objective differences in 3D endoluminal rendering and navigational capabilities exist among the systems evaluated. Of the three, effective time-efficient primary 3D evaluation appears to be feasible only with the V3D-Colon system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Virtual vs. optical colonoscopy in symptomatic gastroenterology out-patients: the case for virtual imaging followed by targeted diagnostic or therapeutic colonoscopy.

AIM To compare virtual colonoscopy with optical colonoscopy findings in symptomatic patients. BACKGROUND Computer tomographic colonography is an alternative to optical colonoscopy. Studies have shown that two-dimensional computer tomographic colonography does not have sufficient sensitivity. Three-dimensional computerized tomographic virtual colonoscopy compares well with optical colonoscopy ...

متن کامل

Double Colorectal Cancer Only Diagnosed by Computed Tomographic Colonography

A 58-year-old woman presented to her physician with rectal bleeding and intermittent diarrhea. Optical colonoscopy revealed a bulky tumor which was diagnosed as rectal cancer. She was referred to our institution for further evaluation and treatment. Slim optical colonoscopy showed an obstructive cancer in the rectosigmoid junction and no information of the proximal side of the obstruction. The ...

متن کامل

Three-dimensional virtual dissection at CT colonography: unraveling the colon to search for lesions.

Computed tomographic (CT) colonography is a promising noninvasive examination for colorectal cancer screening; however, the optimal interpretation strategy remains undecided. Virtual dissection is an innovative technique whereby the three-dimensional (3D) model of the colon is virtually unrolled, sliced open, and displayed as a flat 3D rendering of the mucosal surface, similar to a gross pathol...

متن کامل

External Clinical Validation of Prone and Supine CT Colonography Registration

This paper provides an external validation of a prone-supine registration algorithm for CT colonography (CTC). A validation sample of 49 patient cases with 66 polyps (6 to 30mm) was selected from a publicly available, anonymized CTC archive. To enhance generalizability, no case was excluded due to poor preparation or inadequate distension. Corresponding prone and supine polyp coordinates were r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 181 6  شماره 

صفحات  -

تاریخ انتشار 2003