Use of two oximeters to investigate a method of movement artefact rejection using photoplethysmographic signals.

نویسندگان

  • A R Visram
  • R D Jones
  • M G Irwin
  • J Bacon-Shone
چکیده

Oxygen haemoglobin saturations and plethysmograph signal amplitudes were recorded from two oximeters placed on the fingers and toes of 10 patients undergoing oesophagectomy, to assess a method of removing motion artefact from saturation recordings. By examining changes in the plethysmograph amplitude that preceded changes in saturation, episodes of desaturation caused by movement artefacts were removed from the data. The reliability of the method was then determined by scrutinizing two concurrent oximetric profiles from each patient. A total of 1600 h of data were evaluated. Desaturations occurring contemporaneously in both oxygen saturation profiles were presumed genuine, whereas a desaturation occurring in only one of the profiles was classified as artefactual. Our method had a sensitivity of 96%, a positive predictive power of 98% and a specificity of 60%. We modified the method to increase specificity and re-evaluated our data. We found that a useful increase in specificity was associated with a considerable decline in sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method

Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...

متن کامل

Arterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion

Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...

متن کامل

Fir Filter Design for Removal of Ventilator Artefact in Oesophageal Photoplethysmographic Signals

The oesophagus has been found to be a reliable monitoring site for blood oxygen saturation (SpO2) in anaesthetised patients. Despite it being a very well perfused organ, it was not possible to estimate SpO2 in the lower to deep oesophagus due to movement artefact caused by the mechanical ventilator. This limitation made the measurements more difficult since the probe had to be placed carefully ...

متن کامل

Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.

Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in pha...

متن کامل

Using Eye Movement Analysis to Study Auditory Effects on Visual Memory Recall

Recent studies in affective computing are focused on sensing human cognitive context using biosignals. In this study, electrooculography (EOG) was utilized to investigate memory recall accessibility via eye movement patterns. 12 subjects were participated in our experiment wherein pictures from four categories were presented. Each category contained nine pictures of which three were presented t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 72 4  شماره 

صفحات  -

تاریخ انتشار 1994