Three-dimensional remodelling to determine best fit for hemihamate autograft arthroplasty.
نویسندگان
چکیده
OBJECTIVE To determine the best fit of a hamate osteochondral graft to reconstruct a palmar defect of a middle phalanx articular fracture using three-dimensional remodelling. METHODS The proximal middle phalanx and distal hamate articular surfaces of 10 cadaveric right hands were scanned using a three-dimensional laser scanner. A defect was marked on the middle phalanx digital image to simulate a 50% palmar lip fracture. A hemihamate autograft surgical procedure was simulated by aligning the middle phalanx and hamate digital articular surfaces. In addition to the second digit measurements, the midpoint distances of the central ridge of proximal articular surface of the middle phalanx digital image for digits 3, 4 and 5 were recorded for reference value, as well as the offset distances for the long and small finger. RESULTS The mean midpoint distance for the index finger was 2.96 mm (95% CI 2.71 mm to 3.21 mm). The mean angle of offset was 20.09° (95% CI 15.54° to 24.64°). The mean graft offset distance was prominent by 1.23 mm (95% CI 0.57 mm to 1.89 mm). The reference values for the third, fourth and fifth middle phalange midpoint distances were 3.26 mm (95% CI 3.09 mm to 3.43 mm), 3.13 mm (95% CI 2.93 mm to 3.33 mm) and 2.48 mm (95% CI 2.33 mm to 2.63 mm), respectively. The offset distances for digits 3 and 5 were 1.24 mm (95% CI 0.48 mm to 2.00 mm) and 1.08 mm (95% CI 0.48 mm to 1.68 mm), respectively. CONCLUSIONS The present study provides information about best fit for placing a hamate autograft for the hemihamate arthroplasty procedure. In this model, the hamate graft must be offset to recreate the curvature of the middle phalanx.
منابع مشابه
Bone Remodelling of the Humerus after a Shoulder Arthroplasty
In this work computational models are developed to analyze bone remodeling of the humerus after a shoulder arthroplasty using either a cemented or press-fit stem. Bone is modelled as a porous material, characterized by its local density. The bone remodelling model is based on a global optimization criterion by the minimization of a function which takes into account both structural stiffness and...
متن کاملTreatment of Proximal Interphalangeal (PIP) Joint Fracture By Dynamic Kirschner Wire Fixator
Proximal interphalangeal (PIP) joint injuries remain challenging to hand surgeons [1]. Painless, stable and mobile PIP joint are the main goals for any treatment option of PIP joint [2,3]. Closed reduction and extension block pins [1,2] Open reduction of PIP joint fractures [3,4] and osteochondral hemihamate autograft arthroplasty [5,6] described for treatment of such difficult injuries. Mainte...
متن کاملDorsal proximal interphalangeal joint fracture-dislocations: evaluation and treatment.
Proximal interphalangeal joint injuries are common and often can be treated nonsurgically. Some dorsal fracture-dislocations, however, require special attention or surgical management to optimize outcomes. Treatment options for dorsal proximal interphalangeal fracture-dislocations include splinting, percutaneous pinning, fracture fixation, external fixation devices, volar plate arthroplasty, an...
متن کاملPrediction Of The Primary Stem Stability For Total Hip Arthroplasty Using Numerical Modal Analysis Based On Preoperative Computerised Three- dimensional Planning
Introduction: Cementless total hip arthroplasty involves a press-fit condition between the stem and the femur. The primary stem stability is crucial in order to achieve bone in-growth and good functional outcomes especially in the early post-operative period. The stem stability is usually assessed intuitively by the surgeon at the time of the surgical procedure with an inherent risk of size err...
متن کاملCorrelation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling.
Periprosthetic adaptive bone remodelling after total hip arthroplasty can be simulated in computer models, combining bone remodelling theory with finite element analysis. Patient specific three-dimensional finite element models of retrieved bone specimens from an earlier bone densitometry (DEXA) study were constructed and bone remodelling simulations performed. Results of the simulations were a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Plastic surgery
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2014