Reduction of gaseous microembolism during aortic valve replacement using a dynamic bubble trap.

نویسندگان

  • M Schönburg
  • T Ziegelhoeffer
  • B Kraus
  • A Mühling
  • M Heidt
  • U Taborski
  • T Gerriets
  • M Roth
  • S Hein
  • S Urbanek
  • W P Klövekorn
چکیده

Serious postoperative psycho-neurological dysfunction is at least partially attributed to the occurrence of gaseous microbubbles in the arterial line of extracorporeal circulation (ECC). Therefore, we investigated in a prospective randomized double blind study whether the usage of dynamic bubble trap (DBT) will reduce microbubble load of patients undergoing aortic valve replacement. Patients (n = 41) were divided into group I (GI, n = 22) with DBT introduced into the arterial line of ECC and group II (GII, n = 19) with placebo-DBT instead. Doppler ultrasonography was used for detection of microbubbles before and after DBT, and for detection of high intensity transient signals (HITS) within the middle cerebral artery. The recording time during ECC was divided into period 1 (P1, until aortic clamp removal) and period 2 (P2, clamp removal until the end of ECC). A significant reduction of microbubble load was found in GI only (p < 0.0001 for ECC; p < 0.0001 for P1; p < 0.0025 for P2). A significant difference in number of HITS between the groups was observed in P1 only (p < 0.002 left middle cerebral artery, p < 0.005 right middle cerebral artery), since in P2 the trapped air in left chamber can go to the supraaortal vessels without passing ECC. In conclusion the use of DBT cannot substitute careful venting after aortic declamping. Nevertheless, reduction of HITS in the cross-clamped period of ECC justifies the use of DBT in patients undergoing open chamber surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Comparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery

Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • General physiology and biophysics

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2006