Carbon dioxide gas arthrography for the evaluation of pediatric hip conditions: what is the risk and reliability?

نویسندگان

  • Raymond Chan
  • John Schlechter
  • Shawn Nguyen
  • Francois Lalonde
  • Carl Weinert
چکیده

BACKGROUND Various pediatric conditions often necessitate a morphologic examination of the hip joint in infancy or childhood, and multiple imaging options have been employed to achieve this goal. Arthrography is one such modality. Different types of contrast media have been utilized and include pharmacologic contrast agents, air, and carbon dioxide. There are scattered reports of complications related to the typical various media used during arthrography. Some of the most concerning are related to gas emboli following the use of air or carbon dioxide. This study assesses the potential complications of carbon dioxide hip arthrography in a series of children over a 12-year period. METHODS A retrospective review of the medical records of children between the ages of 0 and 3 years who underwent hip arthrography using carbon dioxide gas as the contrast medium was conducted. Outcome measures analyzed included volume of CO2 injected, vital signs, and perioperative and postoperative end-tidal CO2. RESULTS Our study population was comprised of 118 hips in 90 children. We found no correlation between the volume of CO2 injected and the patient's vital signs or end-tidal CO2 at any point during the perioperative or postoperative period. None of the children exhibited any evidence for cardiopulmonary compromise or clinical signs of embolism. DISCUSSION To our knowledge, there have been no large studies reporting on carbon dioxide arthrography and its potential complications. There were no gas embolisms and/or cardiopulmonary complications in our patients in the perioperative, postoperative, or 1-year follow-up period. Utilizing carbon dioxide gas as the contrast media for hip arthrography in children is safe and can help aid in the treatment of pediatric hip conditions. LEVEL OF EVIDENCE Therapeutic Level IV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor

comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...

متن کامل

CARBON DIOXIDE MINIMUM MISCIBILITY PRESSURE ESTIMATION (CASE STUDY)

Carbon dioxide flooding is considered to be one of the most effective enhanced oil recovery methods for the light oil reservoirs. Depending on the operating pressure, the process might be miscible or immiscible. Minimum miscibility pressure (MMP) is the most important parameter for assessing the applicability of any miscible gas flood for an oil reservoir. The miscibility condition is determine...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

Experimental, Kinetics and Isotherm Modeling of Carbon Dioxide Adsorption with 13X Zeolite in a fixed bed column

In this work, zeolite 13X with porosity structure has been used as an adsorbent for adsorption of CO2 flue gas. The effect of operating conditions including pressure and time on adsorption capacity were investigated. The experiments conditions are constant temperature, the range of pressure 1 - 9 bar and the registration of adsorption capacity with passing of time. Experimental data were adjust...

متن کامل

Exergy and Energy Analysis of Effective Utilization of Carbon Dioxide in the Gas-to-Methanol Process

Two process models are used to convert carbon dioxide into methanol. These processes have been extended and improved using Aspen Plus simulator software. Both processes are found in the CO2 correction system. In this machine, the desired synthesis gas is produced in a flexible configuration. At the same time, the conversion of CO2 to hydrogen via a copper-based catalyst ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2014