Hard-x-ray lensless imaging of extended objects.

نویسندگان

  • J M Rodenburg
  • A C Hurst
  • A G Cullis
  • B R Dobson
  • F Pfeiffer
  • O Bunk
  • C David
  • K Jefimovs
  • I Johnson
چکیده

We demonstrate a hard-x-ray microscope that does not use a lens and is not limited to a small field of view or an object of finite size. The method does not suffer any of the physical constraints, convergence problems, or defocus ambiguities that often arise in conventional phase-retrieval diffractive imaging techniques. Calculation times are about a thousand times shorter than in current iterative algorithms. We need no a priori knowledge about the object, which can be a transmission function with both modulus and phase components. The technique has revolutionary implications for x-ray imaging of all classes of specimen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal signal-to-noise ratios for soft x-ray lensless imaging.

We propose and demonstrate a method to gauge and optimize the signal-to-noise ratios (SNRs) in lensless imaging using partially coherent sources. Through spatial filtering we tuned the coherence width of an incoherent soft x-ray undulator source, and we deduce that there exists an optimal spatial filter setting for imaging micrometer-sized objects, while high-resolution imaging is best executed...

متن کامل

Fourier-Transform Ghost Imaging with Hard X Rays.

Knowledge gained through x-ray crystallography fostered structural determination of materials and greatly facilitated the development of modern science and technology in the past century. However, it is only applied to crystalline structures and cannot resolve noncrystalline materials. Here we demonstrate a novel lensless Fourier-transform ghost imaging method with pseudothermal hard x rays tha...

متن کامل

A scheme for lensless X-ray microscopy combining coherent diffraction imaging and differential corner holography.

We successfully use the corners of a common silicon nitride supporting window in lensless X-ray microscopy as extended references in differential holography to obtain a real space hologram of the illuminated object. Moreover, we combine this method with the iterative phasing techniques of coherent diffraction imaging to enhance the spatial resolution on the reconstructed object, and overcome th...

متن کامل

Single-shot femtosecond x-ray holography using extended references.

In the context of x-ray lensless imaging, we present a recent approach for Fourier transform holography based on the use of extended references. Major advances shown here rely on a high signal efficiency and on the direct image reconstruction of the object performed by a simple linear derivative. Moreover, the extended holographic reference is easy to manufacture and can be applied to a variety...

متن کامل

Three-dimensional visualization of a human chromosome using coherent X-ray diffraction.

Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 98 3  شماره 

صفحات  -

تاریخ انتشار 2007