Development and Validation of RP-HPLC Method for Simultaneous Estimation of Cefpodoxime Proxetil and Dicloxacillin Sodium in Tablets

نویسندگان

  • D. R. Acharya
  • Dipti B. Patel
چکیده

A simple, accurate, rapid and precise reversed-phase high-performance liquid chromatographic method has been developed and validated for simultaneous determination of cefpodoxime proxetil and dicloxacillin sodium in tablet. The chromatographic separation was carried out on kromasil C18 analytical column (250×4.6 mm; 5 μm) with a mixture of acetonitrile:methanol:trifloroacetic acid (0.001%) with pH 6.5 (30:50:20, v/v/v) as mobile phase; at a flow rate of 1.0 ml/min. UV detection was performed at 235 nm. The dicloxacillin sodium and cefpodoxime proxetil were eluted at 1.92 and 3.35 min, respectively. The peaks were eluted with better resolution. Calibration plots were linear over the concentration range 0.5-20 μg/ml for cefpodoxime proxetil (r(2)=0.9996) and 5-50 μg/ml for dicloxacillin sodium (r(2)=0.9987). The method was validated for accuracy, precision, linearity and specificity. The method was very sensitive with limit of detection 0.0726, 0.3685 μg/ml and limit of quantification 0.220, 1.116 μg/ml for cefpodoxime proxetil and dicloxacillin sodium, respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of cefpodoxime proxetil and dicloxacillin sodium in bulk drug and tablet dosage form.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form

The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...

متن کامل

Simultaneous RP-HPLC Estimation of Cefpodoxime Proxetil and Clavulanic Acid in Tablets

A new, simple, precise, rapid and accurate RP-HPLC method has been developed for the simultaneous estimation of cefpodoxime proxetil and clavulanic acid from pharmaceutical dosage forms. The method was carried out on a Zorbax Eclipse XDB 5 mu C 18 (150x4.6 mm) column with a mobile phase consisting of acetonitrile:50 mM potassium dihydrogen phosphate buffer (pH 3.0, 70:30 v/v) at a flow rate of ...

متن کامل

Development and Validation of Spectrophotometric Method for Simultaneous Determination of Cefpodoxime Proxetil and Ofloxacin in Tablets

The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of cefpodoxime proxetil and ofloxacin in combined tablet dosage form. The method is based on the simultaneous equations for analysis of both the drugs using methanol as solvent. Cefpodoxime proxetil has absorabance maxima at 236 nm and ofloxaci...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013