In vitro specular microscope perfusion of M-K- and moist chamber-stored human corneas.

نویسنده

  • B E McCarey
چکیده

Human donor corneas were stored in McCarey-Kaufman (M-K) medium for 3 to 6 days; then they were mounted in the specular microscope, and the endothelial surface perfused with a glutathione-bicarbonate-Ringer solution. During storage, the corneal thickness increased 37% above an assumed normal of 0.520 mm. The corneas did not have sufficient active thinning to be accepted as viable when tested by the temperature-reversal phenomenon. Since comparable donor corneas have been used in successful penetrating keratoplasties, there must be a discrepancy between the cell viability as tested by the temperature-reversal phenomenon and clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intermediate-term corneal storage.

Human and rabbit corneas were evaluated for suitability for keratoplasty donor material after storage in moist chambers or soaked in various media. A new chamber was designed which allows corneas to be stored for up to two weeks at ordinary refrigerator temperature. Corneas with scleral rims were placed in the chamber at 4° C. The epithelium faced down into the medium of modified Ringer's or ph...

متن کامل

Ultrastructure of M-K and refrigerated moist chamber-stored corneas.

McCarey and Kaufman have developed a technique for storing donor corneas by immersing the cornea with its scleral rim in a specific M-K bathing media. By histologic comparison, the M-K media-stored rabbit corneas are superior to the refrigerated moist chamber-stored rabbit corneas. They maintained normal cytoplasmic density but vacuoles and mitochondria swelling were present. In the moist chamb...

متن کامل

Reports: Ultrastructure of M-K and Refrigerated Moist Chamber-Stored Corneas

McCarey and Kaufman have developed a technique for storing donor corneas by immersing the cornea with its scleral rim in a specific M-K bathing media. By histologic comparison, the M-K media-stored rabbit corneas are superior to the refrigerated moist chamber-stored rabbit corneas. They maintained normal cytoplasmic density but vacuoles and mitochondria swelling were present. In the moist chamb...

متن کامل

A simple corneal perfusion chamber for drug penetration and toxicity studies.

AIMS Corneal perfusion chambers are important tools in the development and assessment of ophthalmic drugs. The aim of this study was to design and test a modified perfusion chamber suitable for topical application of drugs to isolated corneoscleral preparations, and which allowed continuous monitoring of endothelial cell function. METHODS A polycarbonate and stainless steel perfusion chamber ...

متن کامل

Intracellular pH and glutathione levels in rabbit corneal endothelium following storage in moist chamber and MK medium.

Rabbit corneas were stored for up to 14 days at 4 C either as the whole eye in a moist chamber or as the isolated cornea in MK medium with HEPES buffer. The intracellular pH, the glutathione content, and its oxidation state were determined in the endothelial cells of fresh and stored tissue. The endothelial pH was found to be unchanged following storage of up to 7 days by either method, but aft...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 16 8  شماره 

صفحات  -

تاریخ انتشار 1977