Influence of an Air Gap between Bolus and Patient Skin on Electron Beam Dose Characteristics

نویسنده

  • G. Kohler
چکیده

Introduction In electron beam therapy bolus is often used to conform as closely as possible to the target volume while avoiding critical structures in the depth. In most cases a flexible bolus can cover the skin without air gap. However, under certain conditions it is difficult –or even not possible– to avoid air gaps between bolus and patient without reducing treatment quality. In a special clinical case in our hospital (USB) bolus was used in the neck region in combination with a head fixation. The fixation grid was not in contact with the patient skin in the treatment region but the bolus was attached outside the grid resulting in an air gap behind the bolus. Such an air gap can affect dose and dose distribution [1]. The aim of the current investigation is to evaluate the effects of an air gap behind a bolus on dose and dose distribution characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of air gaps between bolus and skin on the dose received from the skin

    Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. For close - to - surface tumors, the surface of the skin can be used to increase the surface dose so that all or part of the bunch area can fall into bolus, thereby increasing the dose of the skin. The air gaps between bolus and skin can affect the dose of...

متن کامل

Investigating The Role of Helium Bag On Electron Contamination Removal Using Beam NRC

  Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...

متن کامل

Dosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy

Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which ...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Evaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac

Introduction:  Skin  sparing  is  one  of  the  most  desirable  characteristics  of  high  energy  photon  beams. However, the photons emerging from the target of linacs are contaminated by secondary  electrons  as  a  result  of  their  interactions  with  air,  collimators,  flattening  filter  and  any  other  objects in their path. This phenomenon tends to increase the skin dose received b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009