Implementation of an implantable joint-angle transducer.
نویسندگان
چکیده
An implantable joint-angle transducer (IJAT) was implemented to provide command-control information from the wrist for functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses the Hall effect to sense joint angle. The objectives of this study were to evaluate (1) chronic functionality, (2) safety and biocompatibility, (3) repeatability of the implantation procedure, and (4) clinical feasibility. Accelerated bench testing projected an operating period of over 50 years. In chronic animal experiments, stable output was obtained from three of four IJATs for periods of 10 to 19 months. Histology revealed acceptable osseointegration of the implant. The device has been implanted in human subjects for over 2 years and provides an excellent control signal for hand grasp. We conclude that this device is safe and effective for chronic human use as a control input for an implanted hand neuroprosthesis.
منابع مشابه
Wireless wearable controller for upper-limb neuroprosthesis.
The objective of this project was to develop a wireless, wearable joint angle transducer to enable proportional control of an upper-limb neuroprosthesis by wrist position. Implanted neuroprostheses use functional electrical stimulation to provide hand grasp to individuals with tetraplegia. Wrist position is advantageous for control because it augments the tenodesis grasp and can be implemented ...
متن کاملImplementation of a direct install 3-pole type EM transducer in round window niche for implantable middle ear hearing aids.
Since the 1980's, various types of implantable hearing aids using unique means for delivering acoustic power to the inner ear have been developed. Recently, implantable hearing aids that stimulate the round window by the middle ear transducer have received great attention because it reduces loading effect at the ossicular chain. In this study, we have implemented a direct install 3-pole type EM...
متن کاملExamination of a Mechanical Amplifier in the Incudostapedial Joint Gap: FEM Simulation and Physical Model
Implantable assembly components that are biocompatible and highly miniaturized are an important objective for hearing aid development. We introduce a mechanical transducer, which could be suitable as part of a prospective fully-implantable hearing aid. The transducer comprises a sensor and an actuator unit in one housing, located in the joint gap between the middle ear ossicles, the incus and s...
متن کاملDevelopment of an optical fiber transducer applied to the measurement of finger movements
A flexible and low-cost optical fiber transducer based on light attenuation by microbending was designed for the measurement of angular displacements. The transducer was tested for predetermined rotations, presenting a higher sensitivity for angles >10° by spacing the periodicity of the deformers by 2 mm. In addition, the performance on the measurement of angles <10° was also enhanced by the sp...
متن کاملResearch Paper: Anthropometric Study of Hip Joint in Tehran Population Using Computed Tomography Scan
Introduction: Anthropometric studies provide valuable information in different populations. This study was conducted to evaluate the anatomical variations of the normal hip joint among Tehran population, Iran, in comparison with other populations. Methods: This study was carried out on hip joint of 260 patients in all ages and both genders referred to the Department of Radiology at Ebn-e Sina ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2002