Dual-energy X-ray absorptiometry-based body volume measurement for 4-compartment body composition.

نویسندگان

  • Joseph P Wilson
  • Kathleen Mulligan
  • Bo Fan
  • Jennifer L Sherman
  • Elizabeth J Murphy
  • Viva W Tai
  • Cassidy L Powers
  • Lorena Marquez
  • Viviana Ruiz-Barros
  • John A Shepherd
چکیده

BACKGROUND Total body volume (TBV), with the exclusion of internal air voids, is necessary to quantify body composition in Lohman's 4-compartment (4C) model. OBJECTIVE This investigation sought to derive a novel, TBV measure with the use of only dual-energy X-ray absorptiometry (DXA) attenuation values for use in Lohman's 4C body composition model. DESIGN Pixel-specific masses and volumes were calculated from low- and high-energy attenuation values with the use of first principle conversions of mass attenuation coefficients. Pixel masses and volumes were summed to derive body mass and total body volume. As proof of concept, 11 participants were recruited to have 4C measures taken: DXA, air-displacement plethysmography (ADP), and total body water (TBW). TBV measures with the use of only DXA (DXA-volume) and ADP-volume measures were compared for each participant. To see how body composition estimates were affected by these 2 methods, we used Lohman's 4C model to quantify percentage fat measures for each participant and compared them with conventional DXA measures. RESULTS DXA-volume and ADP-volume measures were highly correlated (R(2) = 0.99) and showed no statistically significant bias. Percentage fat by DXA volume was highly correlated with ADP-volume percentage fat measures and DXA software-reported percentage fat measures (R(2) = 0.96 and R(2) = 0.98, respectively) but were slightly biased. CONCLUSIONS A novel method to calculate TBV with the use of a clinical DXA system was developed, compared against ADP as proof of principle, and used in Lohman's 4C body composition model. The DXA-volume approach eliminates many of the inherent inaccuracies associated with displacement measures for volume and, if validated in larger groups of participants, would simplify the acquisition of 4C body composition to a single DXA scan and TBW measure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18-45 years.

BACKGROUND Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. OBJECTIVE To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. METHODS Men (n = 25) and women (n = 31), aged 18-41 years, par...

متن کامل

Dual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population

  Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...

متن کامل

Is Digital Image Acquisition (DIP) a Valid New Tool for Preoperative Body Composition Assessment? a Validation by Dual-energy X-ray Absorptiometry

Background: The increasing incidence of obesity and the wider acceptance of laparoscopic surgery, have lead to a 10-fold increase in bariatric operations in the last 10 years. Widely used indices of obesity (weight and body mass index – BMI) cannot adequately distinguish between fat mass (FM), represented by the sum of kilograms (kg) of lipid, and fat-free mass (FFM), inclusive of lean (kg of p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 95 1  شماره 

صفحات  -

تاریخ انتشار 2012