Phase-based Regional Oxygen Metabolism (PROM) at 3T and feasibility at 7T

نویسندگان

  • A. P. Fan
  • T. Benner
  • D. S. Bolar
  • B. R. Rosen
  • E. Adalsteinsson
چکیده

Introduction: The cerebral metabolic rate of oxygen (CMRO2) is an important indicator for brain function and disease, including stroke and tumor. CMRO2 can be quantified from measurements of venous oxygen saturation (Yv) and cerebral blood flow (CBF) in cerebral veins. Bulk susceptibility measurements based on gradient-echo phase maps have been used to estimate Yv in vivo at 3T [1]. Challenges of this technique include partial volume effects, phase wrapping, and background susceptibility gradients. Here we quantify CMRO2 by independently measuring Yv and CBF at 3T using MR susceptometry and arterial spin labeling (ASL). We also demonstrate feasibility of quantifying Yv at 7T, which offers higher-resolution analysis of vessels of interest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase-based Regional Oxygen Metabolism in Magnetic Resonance Imaging at High Field

Venous oxygen saturation (Yv) in cerebral veins and the cerebral metabolic rate of oxygen (CMRO2) are important indicators for brain function and disease. Phase-susceptibility measurements in magnetic resonance imaging (MRI) have been used to quantify Yv in candidate cerebral veins. However, currently there is no method to quantify regional CMRO2 using MRI. Here we propose a novel technique to ...

متن کامل

Feasibility of imaging superficial palmar arch using micro-ultrasound, 7T and 3T magnetic resonance imaging

AIM To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency micro-ultrasound, 7T and 3T magnetic resonance imaging (MRI). METHODS Four subjects (ages 22-50 years) were scanned on a micro-ultrasound system with a 45-MHz transducer (Vevo 2100, VisualSonics). Subjects' hands were then imaged on a 3T clinical MR scanner (Siemens Biograph MMR) using an...

متن کامل

Human cardiac 31P magnetic resonance spectroscopy at 7 tesla

PURPOSE Phosphorus magnetic resonance spectroscopy ((31)P-MRS) affords unique insight into cardiac energetics but has a low intrinsic signal-to-noise ratio (SNR) in humans. Theory predicts an increased (31)P-MRS SNR at 7T, offering exciting possibilities to better investigate cardiac metabolism. We therefore compare the performance of human cardiac (31)P-MRS at 7T to 3T, and measure T1s for (31...

متن کامل

Retinotopic mapping with spin echo BOLD at 7T.

For blood oxygenation level-dependent (BOLD) functional MRI experiments, contrast-to-noise ratio (CNR) increases with increasing field strength for both gradient echo (GE) and spin echo (SE) BOLD techniques. However, susceptibility artifacts and nonuniform coil sensitivity profiles complicate large field-of-view fMRI experiments (e.g., experiments covering multiple visual areas instead of focus...

متن کامل

A New Functional MRI Approach for Investigating Modulations of Brain Oxygen Metabolism

Functional MRI (fMRI) using the blood oxygenation level dependent (BOLD) signal is a common technique in the study of brain function. The BOLD signal is sensitive to the complex interaction of physiological changes including cerebral blood flow (CBF), cerebral blood volume (CBV), and cerebral oxygen metabolism (CMRO2). A primary goal of quantitative fMRI methods is to combine BOLD imaging with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009