Burns to be alive: a complication of transcutaneous cardiac stimulation

نویسنده

  • Xavier Muschart
چکیده

Figure 1 Two little third-degree skin burns under the breast following use of an external cardiac pacing device. External cardiac pacing devices (ECPDs) are commonly employed in emergency situations. The main indication for their use is untolerated bradycardia, especially in cases where other medical treatments have no effect [1]. Although the efficacy and safety of ECPDs are well documented, a classic side effect associated with their use is pain secondary to the electrically induced muscular contraction. Therefore, correct sedation-analgesia is critical for avoiding pain when reaching the correct voltages required for effective electrostimulation. Here, we report the case of an 86-year-old patient with third-degree skin burns secondary to the use of an ECPD (a Zoll M Series Biphasic® defibrillator along with Stat Padz Multi-Function® adult electrodes with high viscosity polymer gel; Zoll Medical Corporation, USA) (Figure 1). To date, this observation represents the most serious ECPD-associated adult complication described in the literature. Electric cardioversion, defibrillation or ECPDs saves lives [1]. In particular, external pacing is indicated for untolerated bradyarrhythmia where medications have no effect. Classic complications of transcutaneous cardiac stimulation are related to electricity [2]. Indeed, electricity can lead to accidental injury of the medical team via lack of precautions and iatrogenic skin burns. However, no ECPD-related skin burn has been described for adults in the literature [3,4]. Although our patient benefited from the use of the ECPD, she acquired severe skin burns as a result of the treatment. Several possible explanations might explain this unusual complication. First of all, we cannot rule out that this issue resulted from a technical problem with the patch or glue. However, a poorly bonded patch or trapped air pockets between the gel and the skin could also be to blame. Additionally, greater impedance due to the breast weight of the patient could constitute a plausible explanation. Finally, the long wait time (2 hours) prior

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does High Frequency Transcutaneous Electrical Nerve Stimulation (TENS) Affect EEG Gamma Band Activity?

Background: Transcutaneous electrical nerve stimulation (TENS) is a noninvasive, inexpensive and safe analgesic technique used for relieving acute and chronic pain. However, despite all these advantages, there has been very little research into the therapeutic effects of TENS on brain activity. To the best of our knowledge, there is no evidence on the effect of high frequency TENS on the gamma ...

متن کامل

Comparative Use of Electromyography in the Evaluation of Electroacupuncture and Transcutaneous Electrical Neural Stimulation (TENS) Effect on Regeneration of Sciatic Nerve in Dog

Objective-To determine the effect of Electroacupuncture and Transcutaneous Electrical Neural Stimulation on Regeneration of Sciatic Nerve in Dog   Design - Experimental in vivo study. Animals - A total of 15 adult male mixed bred dogs, weighing 26±2.6 Kg/BW with aging of 42±6 months, which were divided into three groups of  5 dogs. Procedures-Under general anesthesia, the right sciatic nerv...

متن کامل

Efficacy of Low-Level Laser Versus Transcutaneous Electrical Nerve Stimulation for Treatment of Myofascial Pain Syndrome: A Clinical Trial

Background and Aim: Myofascial pain syndrome (MPS) is the most common cause of facial muscle pain. This study sought to assess the efficacy of transcutaneous electrical nerve stimulation (TENS) and low-level laser (LLL) for treatment of MPS in comparison with a sham laser control group. Materials and Methods: In this randomized controlled clinical trial, 55 MPS patients between 18-60 years old ...

متن کامل

Histomorphological Evaluation of Transcutaneous Electrical Neural Stimulation in Healing of Experimentally Induced Partial Hip Joint Cartilage Defect in Rabbit

Objective- To determine the effect of the transcutaneous electrical neural stimulation on healing of hip joint cartilage defect in rabbit.Design- Experimental in vivo study.Animals- 12 adult New Zealand rabbits were used.Procedures- Under effective the right femoral head was subluxated and the maximum accessible cartilage was denuded up to subchondral bone using dental bit in each rabbit. Then ...

متن کامل

Cumulative Clinical Evaluation of Transcutaneous Blood Laser Irradiation on Hemodynamic Changes in Anesthesia of Dogs

Objectives-The aims of this study were evaluation the effects of blood laser irradiation on hemodynamic parameters, the amount of anesthetic drugs in maintenance of anesthesia and duration of recovery. Animals- Fifteen mixed breed dogs Procedures- dogs (25.0 ± 3.6 kg) were divided into three groups (n=5). The group I was acted as control and received only cold laser. The group II was premedicat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014