Manual and automated methods for urea nitrogen measurement in whole serum.

نویسندگان

  • D R Wybenga
  • J Di Giorgio
  • V J Pileggi
چکیده

A simple method is described for directly determining serum urea nitrogen, wtihout deproteinization. The urea in 20 Ml of serum or plasma is reacted with diacetylmonoxime in the presence of thiosemicarbazide and cadmium ion under acid conditions. The absorbance of the resulting rose-purple solution is measured at 540 nm. Results agreed excellently with those obtained by a reference method that makes use of urease and the Berthelot phenate-hypochlorite reaction for ammonia. An automated adaptation utilizing the AutoAnalyzer is also described, which eliminates the need for a dialyzer. A further advantage is that the same reagents are used for both methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated and Manual Direct Methods for the Determination of Blood Urea.

Automated and manual direct methods for the determination of urea in blood or serum are described. These methods determine urea by the colored product formed when urea, in relatively weak acid solution, reacts with diacetyl monoxime in the presence of thiosemicarbazide and ferric ion. Results are compared with those obtained by urease conversion of urea to ammonia and measurement of the ammonia...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

A single-reagent manual method for directly determining urea nitrogen in serum.

A direct method is described, in which a single reagent is used without deproteinization, for measuring blood urea nitrogen (BUN) in serum. The reagent is a mixture of diacetylmonoxime, antipyrine (phenazone), and arsenic pentoxide in acid solution. Lipemia, bilirubin to 25 mg/100 ml, hemoglobin to 1g/100 ml, and protein to 20g/100 ml do not affect the results. Beer’s law is followed at 460 nm ...

متن کامل

Fragmentation measurement using image processing

In this research, first of all, the existing problems in fragmentation measurement are reviewed for the sake of its fast and reliable evaluation. Then, the available methods used for evaluation of blast results are mentioned. The produced errors especially in recognizing the rock fragments in computer-aided methods, and also, the importance of determination of their sizes in the image analysis ...

متن کامل

اثر سطوح مختلف اوره بر ترکیب شیمیایی و ارزش غذایی سیلاژ ذرت در تغذیه گوسفند

Three levels of urea (0, 0.5 and 0.75% on fresh weight basis) were added to whole corn plants to investigate their effects on the chemical composition, and digestibility in 16 Ghezel male lambs using a completely randomized design. Rumen degradability and nutritive values were also evaluated. pH, total nitrogen and ammonia-N concentration of silages increased (P<0.05) with the addition of urea....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 17 9  شماره 

صفحات  -

تاریخ انتشار 1971