Combined pH-impedance testing for reflux: current state of play and future challenges.
نویسندگان
چکیده
To cite: Sanagapalli S, Sweis R. Frontline Gastroenterology Published Online First: [please include Day Month Year] doi:10.1136/flgastro-2017100840 It is now over 20 years since the introduction of multichannel intraluminal impedance monitoring (MII) in the oesophagus. Its application in children subsequently followed with the widespread availability of paediatric catheters in 2002. MII detects oesophageal bolus movement by measurement of changes in electrical resistance and is used for assessment of reflux in tandem with pH monitoring (MII-pH). MII-pH heralded an advance in our ability to characterise reflux compared with the previous gold standard, pH monitoring alone. Advantages include the ability to detect nonacid and weakly acid reflux, distinguish between antegrade and retrograde bolus movements, differentiate liquid from gas reflux and assess proximal extent of the refluxate. In the intervening period, the translation of this more sophisticated and accurate measurement into improved patient outcomes has, however, not been as demonstrable as would have been hoped for. The BSPGHAN position statement on MII-pH testing, published in the current issue of the journal, highlights the current state of the technology, practical advice for performance of investigations, as well as many issues and controversies that pertain to the use of the technology in the paediatric setting, and often equally to adult practice. The position statement, including its recommendations for practice, was formulated by consensus within a seven-member working group following literature review, but systematic evaluation of the quality of evidence supporting the recommendations was not reported. This probably reflects the low quality and lack of availability of evidence underpinning many of the recommendations. The primary indication for MII-pH in both children and adults remains for the evaluation of refractory reflux symptoms. Its advantage over pH testing alone in this regard is to identify the significant minority of these patients whose symptoms are due to reflux of more than just liquid acid. 4 However, even when nonacid reflux is detected by MII, there is a paucity of evidence linking this finding with positive therapeutic outcomes; this fact applies equally to children and adults. 6 In other words, MII-pH identifies more ‘refluxers’ who might have otherwise be considered functional in nature, but there is little evidence that these extra cases identified benefit from either optimised medical therapy or surgery. It is for this reason that the consensus of the US Esophageal Diagnostic Working Group was that there is insufficient evidence to justify antireflux surgery in adult patients who have an abnormal number of reflux events on MII-pH but no pathological oesophageal acid exposure. In a similar fashion, the use of MII-pH in the evaluation of laryngopharyngeal and respiratory symptoms attributable to GORD has been extensively studied, but its precise role remains somewhat unclear. What is apparent is that there is a definite increase in diagnostic yield with the use of MII-pH compared with pH metry alone, 9 and the increased yield is especially greater in the paediatric population where nonacid and proximal reflux detected by MII-pH seem to play an equally important role as acid reflux. 10 The problem remains, however, that patients with cough attributed to nonacid reflux have poor outcomes from therapy, and therefore the consensus for PROFESSIONAL MATTERS
منابع مشابه
Yield of Combined Impedance-pH Monitoring for Refractory Reflux Symptoms in Clinical Practice
BACKGROUND/AIMS In patients with gastroesophageal reflux disease, persistent symptoms on proton pump inhibitor (PPI) therapy may be due to residual acid or non-acid reflux. Combined impedance-pH has been suggested to be superior to pH alone in the management of refractory patients to PPI. The utility of implementation of this technique in every day clinical practice is still unknown. The aim of...
متن کاملDiscounting the duration of bolus exposure in impedance testing underestimates acid reflux
BACKGROUND Combined impedance-pH testing (MII) allows for detection of reflux episodes regardless of pH. However impedance-based diagnosis of reflux may not routinely account for duration of the reflux episode. We hypothesize that impedance testing may be less sensitive than pH-testing in detecting acid reflux off therapy as a result of discounting duration of exposure. METHODS Baseline chara...
متن کاملHow Useful the Combined Impedance-pH Monitoring Is for Evaluation of Refractory Reflux Symptoms?
TO THE EDITOR: I read with great interest the paper entitled “Yield of combined impedance-pH monitoring for refractory reflux symptoms in clinical practice” by Karamanolis et al, which was published in April 2011 issue of Journal of Neurogastroenterology and Motility. Esophageal impedance pH monitoring allows detection of reflux of any composition (liquid or gas) and pH (acid, weakly acid or no...
متن کاملEsophageal pH and Combined Impedance-pH Monitoring in Children
Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detectio...
متن کاملCombined Dual Channel Impedance/pH-metry in Patients With Suspected Laryngopharyngeal Reflux
BACKGROUND/AIMS Laryngopharyngeal symptoms of gastroesophageal reflux disease (GERD) such as globus sensation, hoarseness and chronic cough are becoming increasingly recognized. This study was aimed to investigate the diagnostic usefulness of combined dual channel multichannel intraluminal impedance (MII)/pH-metry in 'off-proton pump inhibitor (PPI)' patients with suspected laryngopharyngeal re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Frontline gastroenterology
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2017