Gamma nail in the treatment of closed trochanteric fractures. Results and indications of 121 cases.

نویسندگان

  • I Kempf
  • A Grosse
  • G Taglang
  • E Favreul
چکیده

The Gamma Nail is the latest advance in the treatment of trochanteric fractures based on intramedullary nailing principles during closed procedures. Its design is based on Küntscher's Y-nail and locking intramedullary (IM) nails. This paper reports the results from the first-ever series of 121 patients operated between 1988 and 1990. They were followed until bone union was achieved. The mean patient age was 75 years. Most patients were in poor general health and had unstable fractures. Anatomical preoperative reduction was achieved in 72% of cases. Fixation was good in 66% of cases and acceptable in 27% of cases. Intra-operative complications consisted of nine fractures without consequences. Of the treated patients, 83.4% resumed weight-bearing during the first week. There was one case of deep infection that resolved with treatment. The mortality rate was 12.3% at three months. We noted 7 alunions in varus, 3 in valgus, 2 in external rotation and 1 in internal rotation. There were no cases of non-union. In six cases, the screw had cut out of the femoral head. The drawbacks associated with surgical treatment methods for trochanteric fractures also apply to the Gamma nail. Nevertheless, one of its primary advantages is the possibility of using a closed procedure. When compared to Ender nailing, knee pain is absent and weight-bearing can be achieved in all patients, no matter the fracture type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications in Treatment of 31-A Fractures with Trochanteric Gamma Nail (TGN) Versus Gamma3 Nail (G3N) - A Review of 217 Cases

INTRODUCTION The aim of this study was to clinically evaluate two generations of intramedullary gamma-nail used in the treatment of 31-A femur fractures. MATERIALS AND METHODS In two consecutive series, 117 trochanteric gamma nails (TGN) and 100 Gamma3 nails (G3N) were implanted for the treatment of inter- and subtrochanteric fractures between 2009 and 2011. Clinical and radiological follow-u...

متن کامل

Minimally invasive treatment of trochanteric fractures with intramedullary nails. Technique and results

UNLABELLED The aim of the study was to evaluate the results of minimally invasive treatment of trochanteric fractures with the use of intramedullary nails. PATIENTS AND METHODS From September 2010 to September 2012 we treated 21 patients with pertrochanteric fractures by a minimally invasive technique using the Gamma 3 (Stryker, Howmedica) nail. There were 13 females and 8 men with a mean age...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Complications following Treatment of Trochanteric Fractures with the Gamma3 Nail: Is the Latest Version of Gamma Nail Superior to Its Predecessor?

Gamma nail is a cephalomedullary implant that was developed for the treatment of pertrochanteric hip fractures and has been successfully used for over 20 years. During this period, modifications of design and instrumentation have occurred to combat the intra- and postoperative complications that were associated with the use of early designs. The purpose of this study was to compare the complica...

متن کامل

Failure of the titanium trochanteric gamma nail in ununited metastatic fractures.

Metastatic lesions often occur in the trochanteric region of the femur with a risk for pathologic fractures, requiring aggressive surgical treatment. We present two cases of mechanical failure of the Titanium Gamma 3 Nail 180 used for treatment of impending pertrochanteric pathologic fractures. Metallurgic and low power optical examination findings are presented. Treatment with intramedullary n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 100 1  شماره 

صفحات  -

تاریخ انتشار 2014