1,5-Anhydro-D-Glucitol Could Reflect Hypoglycemia Risk in Patients with Type 2 Diabetes Receiving Insulin Therapy

نویسندگان

  • Min Kyeong Kim
  • Hye Seung Jung
  • Soo Heon Kwak
  • Young Min Cho
  • Kyong Soo Park
  • Seong Yeon Kim
چکیده

BACKGROUND The identification of a marker for hypoglycemia could help patients achieve strict glucose control with a lower risk of hypoglycemia. 1,5-Anhydro-D-glucitol (1,5-AG) reflects postprandial hyperglycemia in patients with well-controlled diabetes, which contributes to glycemic variability. Because glycemic variability is related to hypoglycemia, we aimed to evaluate the value of 1,5-AG as a marker of hypoglycemia. METHODS We enrolled 18 adults with type 2 diabetes mellitus (T2DM) receiving insulin therapy and assessed the occurrence of hypoglycemia within a 3-month period. We measured 1,5-AG level, performed a survey to score the severity of hypoglycemia, and applied a continuous glucose monitoring system (CGMS). RESULTS 1,5-AG was significantly lower in the high hypoglycemia-score group compared to the low-score group. Additionally, the duration of insulin treatment was significantly longer in the high-score group. Subsequent analyses were adjusted by the duration of insulin treatment and mean blood glucose, which was closely associated with both 1,5-AG level and hypoglycemia risk. In adjusted correlation analyses, 1,5-AG was negatively correlated with hypoglycemia score, area under the curve at 80 mg/dL, and low blood glucose index during CGMS (P=0.068, P=0.033, and P=0.060, respectively). CONCLUSION 1,5-AG level was negatively associated with hypoglycemia score determined by recall and with documented hypoglycemia after adjusting for mean glucose and duration of insulin treatment. As a result, this level could be a marker of the risk of hypoglycemia in patients with well-controlled T2DM receiving insulin therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Application of Plasma 1,5-Anhydro-D-glucitol for Monitoring Type 2 Diabetic Patients

AIM Recent data have suggested that effective control of postprandial blood glucose can reduce the risk of macroangiopathic complications of diabetes, especially cardiovascular risk. 1,5-Anhydro-D-glucitol (1,5-AG) has been proposed as a marker of short-term hyperglycaemic excursions. We aimed to evaluate its usefulness in patients with type 2 diabetes and have attempted to indicate when 1,5-AG...

متن کامل

Fully automated flow-injection system for quantifying 1,5-anhydro-D-glucitol in serum.

We have developed a flow-injection system with colorimetric detection to measure 1,5-anhydro-D-glucitol in serum. Serum samples are directly and serially injected into a clean-up column every 3.5 min to remove interferences before the enzymatic reaction. 1,5-Anhydro-D-glucitol, after being passed through the column, is oxidized by immobilized pyranose oxidase (EC 1.1.3.10), and the hydrogen per...

متن کامل

Simple enzymatic method for determining 1,5-anhydro-D-glucitol in plasma for diagnosis of diabetes mellitus.

We have developed a simple method for determination of 1,5-anhydro-D-glucitol in plasma, based on use of pyranose oxidase (EC 1.1.3.10), an enzyme with specificity toward pyranoid compounds such as 1,5-anhydro-D-glucitol and glucose. Plasma samples deproteinized with trichloroacetic acid are passed through a two-layer mini-column packed with strongly basic anion (OH- form, the upper layer) and ...

متن کامل

Low levels of 1,5-anhydro-D-glucitol are associated with vascular endothelial dysfunction in type 2 diabetes

BACKGROUND Vascular endothelial dysfunction is involved in macrovascular disease progression in type 2 diabetes mellitus (T2DM). We reported previously that blood glucose fluctuations, as evaluated by continuous glucose monitoring (CGM), correlate with vascular endothelial function, serving as a marker of vascular endothelial function. However, the use of CGM is limited, suggesting the need for...

متن کامل

Excretion rates of 1,5-anhydro-D-glucitol, uric acid and microalbuminuria as glycemic control indexes in patients with type 2 diabetes

1,5-anhydroglucitol (1,5-AG), uric acid and urinary proteins are excreted into the urine with increasing glucosuria. In the present retrospective study we analyzed whether these factors could be used as indicators for type 2 diabetes mellitus (T2DM) glucose control in 6,766 (T2DM) patients. There were 3,988 cases (58.9%) with HbA1c ≤ 6.5%, 853 cases (12.61%) with HbA1c levels ranging from 6.5% ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2016