Efficacy of a Novel Prefilled, Single-Use, Needle-Free Device (Zeneo®) in Achieving Intramuscular Agent Delivery: An Observational Study

نویسندگان

  • Marc Bardou
  • Maxime Luu
  • Paul Walker
  • Christophe Auriel
  • Xavière Castano
چکیده

BACKGROUND It is recognized that, as a result of variation in tissue anatomy, current auto-injectors may have insufficient needle length to achieve successful intramuscular agent delivery in a number of patients. The Zeneo® auto-injector is a novel prefilled, single-use, needle-free device currently in development for intradermal, subcutaneous, and intramuscular agent delivery across a variety of clinical indications. We aimed to evaluate delivery depth of the device calibrated at pressure appropriate for intramuscular (IM) administration. METHODS This was a prospective single-center study in healthy adult volunteers, in whom each received a single injection of saline into the anterolateral thigh. Using sequential MRI scans, we measured skin-to-muscle distance (STMD) agent delivery depth, and the success of IM agent penetration. Device dynamic pressure measurements were also recorded. RESULTS Results are reported for 37 subjects with evaluable MRI scans; 19 men, 18 women; mean age 38 years (range 20-58); mean BMI 27.0 kg/m2 (range 21.2-30.8 kg/m2). Mean STMD values were 18.6 mm (range 13.4-23.6 mm) in women and 10.0 mm (range 5.0-21.7 mm) in men, with gender differences due primarily to greater subcutaneous thickness in women. A trend for greater STMD in subjects with BMI greater than 25 kg/m2 was seen. Mean injectate penetration depths of 30.1 mm (range 20.2-45.6 mm) were observed with values similar in male and female subjects. Successful IM delivery was reported in 95% of subjects. When failure occurred, this was not due to inadequate injection depth. Device pressure (P max) had the greatest influence on injectate muscle penetration. CONCLUSION Use of the Zeneo® auto-injector achieves delivery depth that ensures intramuscular delivery in both men and women, regardless of BMI. Consistent with other reported data, STMD is greater in women. FUNDING Crossject.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An open-label, multicenter study to evaluate the safe and effective use of the single-use autoinjector with an Avonex® prefilled syringe in multiple sclerosis subjects

BACKGROUND The ability to self-inject in patients with multiple sclerosis (MS) has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patients' independence. However, injection anxiety, needle phobia and disease-related disability are major barriers to a patient's ability to self-administer treatment. Use of an autoinjector may improve ...

متن کامل

O-5: Preparation of Multi-Component Drug Delivery Systems

Background: Despite global interest, the development of single step processes for the preparation of effective drug delivery systems still faces numerous challenges. There is great demand for processing methods that are efficient, flexible, scalable and economical for the generation of wide range of encapsulated structures. Over the past few decades, electrohydrodynamic (EHD) processing has rec...

متن کامل

Pharmacokinetic Profile of Subcutaneous Testosterone Enanthate Delivered via a Novel, Prefilled Single‐Use Autoinjector: A Phase II Study

INTRODUCTION Hypogonadism is one of the most common male endocrine problems. Although many treatments are currently available, unmet need exists for new testosterone (T) replacement therapies that are simple to administer and use, are safe, and mimic physiologic T levels. AIM The study aim was to determine the pharmacokinetics (PK), safety, and tolerability of T enanthate (TE) administered vi...

متن کامل

A novel electroporation device for gene delivery in large animals and humans.

Intramuscular injection of plasmid DNA followed by electrical stimulation (electroporation) is an efficient method for achieving therapeutic levels of encoded proteins or eliciting efficient immune responses in smaller animals such as mice and rats. Electroporation in larger animals and humans poses new technical challenges, the main difficulty being to maintain efficacy while limiting invasive...

متن کامل

Comparison of drug delivery with autoinjector versus manual prefilled syringe and between three different autoinjector devices administered in pig thigh

Parenteral routes of drug administration are often selected to optimize actual dose of drug delivered, assure high bioavailability, bypass first-pass metabolism or harsh gastrointestinal environments, as well as maximize the speed of onset. Intramuscular (IM) delivery can be preferred to intravenous delivery when initiating intravenous access is difficult or impossible. Drugs can be injected in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2017