Kinetic serum creatinine assays. II. A critical evaluation and review.

نویسندگان

  • L D Bowers
  • E T Wong
چکیده

We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffé reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in 92 serum samples; the GEMSAEC method also showed a bias. The positive interference of several acid metabolites was quantitated in each of the methods. The evidence indicates that bilirubin, although associated with a negative creatinine interference, is not the sole interferent. We determined the magnitude of this interference and studied several methods for minimizing it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an Enzymatic Method for Determining Serum Creatinine Assay

The enzymatic method for the determination of serum creatinine is accepted as one of the standard method in a clinical laboratory. The enzymatic method for the determination of serum creatinine was optimized for use with Merilyzer AutoQuant-400 auto analyzer and its performance characteristics were practically compared with Jaffe’s Kinetic. Effects of some interfering substances like Serum bili...

متن کامل

Lactulose interferes in the alkaline picrate assay for creatinine.

Errors of more than 10 mg/L in measured serum creatinine concentrations were encountered for an azotemic patient who was given lactulose orally. The magnitude of the apparent error fluctuated with the dose of lactulose. Additions of lactulose to serum produced a linear increase in the creatinine measured by each of two automated methods that involve use of the alkaline picrate (Jaffé) reaction....

متن کامل

Kinetic serum creatinine assays I. The role of various factors in determining specificity.

We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interferent, the ratio of the rate constants, the extent of the analytical reaction, an...

متن کامل

A multicentric evaluation of IDMS-traceable creatinine enzymatic assays.

Chronic kidney disease definition is based on glomerular filtration rate (GFR) estimations which are derived from creatinine-based equations. The accuracy of GFR estimation is thus largely dependent of those of serum creatinine assays. International recommendations highlight the need for traceable creatinine assays. The French Society of Clinical Biochemistry conducted a study for measuring acc...

متن کامل

Evaluation of the effect of exercise on serum creatinine and urea nitrogen in hemodialysis patients

Introduction. Chronic renal failure is a progressive disease in which kidney function is impaired, so that the body can not metabolize and maintain fluid balance and electrolytes. Therefore, the present study investigated changes in serum creatinine and urea nitrogen in hemodialysis patients in response to exercise. Materials and Methods. The subjects of this study were dialysis patients who we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 1980