Purpose: To investigate the electro-reduction behaviour and determination of ciprofloxacin using a hanging mercury drop electrode. Methods: Cyclic voltammograms of ciprofloxacin recorded in Britton – Robinson buffers pH 2 – 5 exhibit a single irreversible cathodic peak. The dependence of the peak current and peak potential values on buffer (nature, pH and concentration) and accumulation conditions (time and potential) were examined and used for the quantitative analysis of ciprofloxacin in dosage forms and urine. Acetate buffer (0.08 M, pH 3.6) was selected as a supporting electrolyte for quantitative purposes by differential pulse and square wave adsorptive cathodic stripping voltammetry. Results: A reduction wave was seen in the range of – 1.3 to – 1.5 V. These techniques were successfully validated as per ICH guidelines and comparable to US Pharmacopoeia HPLC method. The techniques was applied to the determination of ciprofloxacin in pharmaceutical formulations (i.e. precision (RSD < 1%) and accuracy (99 – 101%)), and was further extended to determine ciprofloxacin in spiked human urine with no matrix effect (i.e. LLOQ 0.01 g/ml, precision (RSD < 15%) and accuracy (85 – 115%)). Conclusion: Validated adsorptive cathodic stripping voltammetric technique can be recommended for use in quality control and pharmacokinetics studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine

The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3-6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled. Britton-Robinson buffer 0.04 M pH 4.0 was selected as a supporting electrolyte for quantitative p...

متن کامل

Cathodic adsorptive stripping voltammetric determination of prednisolone in pharmaceutical preparation and human urine.

Differential pulse cathodic adsorptive stripping voltammetric method was developed for the determination of prednisolone based on electrochemical reduction of the drug at a hanging mercury drop electrode (HMDE) in 0.04 M Britton-Robinson buffer pH 3.5. The peak current varied linearly over the concentration range 7.21-144.2 ng/ml prednisolone with limit of detection and limit of quantification ...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Determination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange

Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013