Characterizing and Improving a Semiportable Mass Spectrometer System for Measurements of Noble Gas Ratios
نویسنده
چکیده
......................................................................................................................................... 1 Chapter 1: Introduction ............................................................................................................... 2 1.1. Background .......................................................................................................................... 2 1.2 Case Studies: The Noble Gases as Geochemical Tracers ..................................................... 6 1.2.1 Noble Gases in Ice Cores................................................................................................ 6 1.2.2 Application of Noble Gases to Determine the Viability of CO2 Storage ....................... 6 1.3 Henry’s Law: Atmospheric Noble Gases and Solubility Equilibria ..................................... 8 1.4 Deviations from Henry’s Law Equilibrium .......................................................................... 9 1.5 Analytical Techniques in the Detection of Noble Gases ..................................................... 10 Chapter 2: Methods .................................................................................................................... 13 2.1 Sample Preparation ............................................................................................................. 14 2.1.1 Flask Samples ............................................................................................................... 14 2.1.2 Bottled Samples for Accuracy Experiments ................................................................. 15 2.2 Processing Line ................................................................................................................... 16 2.2.1 Water Flow Configuration (a, b) .................................................................................. 16 2.2.2 Gas Extraction Membrane (c) ....................................................................................... 17 2.2.3 Gas Purification (d, e) ................................................................................................... 18 2.2.4 Vacuum System (f, h) ................................................................................................... 21 2.2.5 Quadrupole Mass Spectrometer (g) .............................................................................. 21 2.3 Procedures for Precision and Accuracy Experiments ......................................................... 21 2.3.1 Procedure for Precision Experiments ........................................................................... 21 2.3.2 Procedure for Accuracy Experiments ........................................................................... 25 2.4 Sample Analysis .................................................................................................................. 26 2.4.1 Mass Spectrometer ....................................................................................................... 26
منابع مشابه
Continuous Measurements of Dissolved Ne, Ar, Kr, and Xe Ratios with a Field-Deployable Gas Equilibration Mass Spectrometer.
Noble gases dissolved in natural waters are useful tracers for quantifying physical processes. Here, we describe a field-deployable gas equilibration mass spectrometer (GEMS) that provides continuous, real-time measurements of Ne, Ar, Kr, and Xe mole ratios in natural waters. Gas is equilibrated with a membrane contactor cartridge and measured with a quadrupole mass spectrometer, after in-line ...
متن کاملThe Gas Chromatograph Mass Spectrometer for the Huygens Probe
The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of Titan’s atmosphere from 170 km altitude (∼1 hPa) to the surface (∼1500 hPa) and determine the isotope ratios of the major gaseous constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to investigate the composition (including isot...
متن کاملReal-time Diffusive Losses of Light Noble Gases from Genesis Aluminum
Introduction: The Genesis mission returned samples of solar wind (SW) collected over 2 years at the L1 point for earth-based laboratory measurements. The main goal of the mission is to obtain accurate, high precision isotopic measurements of trace elements in the SW [1]. Since there are several processes and effects that can alter the laboratory measured value from the true SW value, it is wort...
متن کاملSequential V(A)/Q distributions in the normal rabbit by micropore membrane inlet mass spectrometry.
We developed micropore membrane inlet mass spectrometer (MMIMS) probes to rapidly measure inert-gas partial pressures in small blood samples. The mass spectrometer output was linearly related to inert-gas partial pressure (r(2) of 0.996-1.000) and was nearly independent of large variations in inert-gas solubility in liquid samples. We infused six inert gases into five pentobarbital-anesthetized...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...