Geometric evaluation of systematic transrectal ultrasound guided prostate biopsy.

نویسندگان

  • Misop Han
  • Doyoung Chang
  • Chunwoo Kim
  • Brian J Lee
  • Yihe Zuo
  • Hyung-Joo Kim
  • Doru Petrisor
  • Bruce Trock
  • Alan W Partin
  • Ronald Rodriguez
  • H Ballentine Carter
  • Mohamad Allaf
  • Jongwon Kim
  • Dan Stoianovici
چکیده

PURPOSE Transrectal ultrasound guided prostate biopsy results rely on physician ability to target the gland according to the biopsy schema. However, to our knowledge it is unknown how accurately the freehand, transrectal ultrasound guided biopsy cores are placed in the prostate and how the geometric distribution of biopsy cores may affect the prostate cancer detection rate. MATERIALS AND METHODS To determine the geometric distribution of cores, we developed a biopsy simulation system with pelvic mock-ups and an optical tracking system. Mock-ups were biopsied in a freehand manner by 5 urologists and by our transrectal ultrasound robot, which can support and move the transrectal ultrasound probe. We compared 1) targeting errors, 2) the accuracy and precision of repeat biopsies, and 3) the estimated significant prostate cancer (0.5 cm(3) or greater) detection rate using a probability based model. RESULTS Urologists biopsied cores in clustered patterns and under sampled a significant portion of the prostate. The robot closely followed the predefined biopsy schema. The mean targeting error of the urologists and the robot was 9.0 and 1.0 mm, respectively. Robotic assistance significantly decreased repeat biopsy errors with improved accuracy and precision. The mean significant prostate cancer detection rate of the urologists and the robot was 36% and 43%, respectively (p <0.0001). CONCLUSIONS Systematic biopsy with freehand transrectal ultrasound guidance does not closely follow the sextant schema and may result in suboptimal sampling and cancer detection. Repeat freehand biopsy of the same target is challenging. Robotic assistance with optimized biopsy schemas can potentially improve targeting, precision and accuracy. A clinical trial is needed to confirm the additional benefits of robotic assistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion of transrectal ultrasound with pre-acquired MRI for prostate biopsy guidance

The fi rst stages of prostate cancer screening and diagnosis involve a digital rectal examination and prostate-specifi c antigen (PSA) test, followed by a transrectal ultrasound (TRUS) examination and, if necessary, a TRUS-guided biopsy. Since the accuracy of TRUS in depicting prostate cancer is insuffi cient, biopsies are generally not lesion-targeted. Instead, the vast majority of biopsies ar...

متن کامل

Transrectal real-time elastography-guided transperineal prostate biopsy as an improved tool for prostate cancer diagnosis.

OBJECTIVES The aim of this study is to determine the utility of transrectal real-time elastography (TRTE)-guided prostate biopsies in patients subjected to transrectal ultrasound (TRUS)-guided transperineal prostate biopsies. MATERIALS AND METHODS A total of 108 consecutive patients suspicious for prostate cancer (PCa) with elevated serum prostate specific antigen (PSA) level > 4 μg/L or abno...

متن کامل

Transrectal ultrasound and biopsy in the early diagnosis of prostate cancer.

BACKGROUND Historically, the prostate was evaluated for cancer by simple digital rectal examination, and biopsy to obtain a tissue diagnosis of cancer was performed blindly. The advent of ultrasound technology offered a new way to evaluate the prostate, and biopsy techniques were soon developed to incorporate ultrasound guidance. METHODS The authors review the role of transrectal ultrasound (...

متن کامل

Comparison of power Doppler ultrasound with gray scale transrectal ultrasound in predicting cancer positive prostate biopsy cores.

OBJECTIVE The aim of this study is to compare the effect of transrectal power Doppler ultrasound (PDUS) and gray scale transrectal ultrasound (TRUS) for the diagnosis of prostate cancer. MATERIALS AND METHODS Seventy-six patients evaluated with transrectal PDUS and TRUS underwent eight systematic TRUS guided core-needle biopsies, with additional cores from abnormal areas. Histologic diagnoses...

متن کامل

[MRI/US-fusion for targeted prostate biopsy].

An innovative fusion of previously acquired magnetic resonance imaging (MRI) images with real-time transrectal ultrasound (US) may lead to improved prostate cancer detection, thus necessitating fewer biopsies. Suspicious lesions can be identified, localised - and possibly classified - via an MRI scan. Subsequently, a biopsy needle can be guided accurately into the suspicious area of the prostat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of urology

دوره 188 6  شماره 

صفحات  -

تاریخ انتشار 2012