Unusually Stable Helical Coil Allotrope of Phosphorus.

نویسندگان

  • Dan Liu
  • Jie Guan
  • Jingwei Jiang
  • David Tománek
چکیده

We have identified an unusually stable helical coil allotrope of phosphorus. Our ab initio density functional theory calculations indicate that the uncoiled, isolated straight one-dimensional chain is equally stable as a monolayer of black phosphorus dubbed phosphorene. The coiling tendency and the attraction between adjacent coil segments add an extra stabilization energy of ∼12 meV/atom to the coil allotrope, similar in value to the ∼16 meV/atom interlayer attraction in bulk black phosphorus. Thus, the helical coil structure is essentially as stable as black phosphorus, the most stable phosphorus allotrope known to date. With an optimum radius of 2.4 nm, the helical coil of phosphorus may fit well and even form inside wide carbon nanotubes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Natural Convection from a Helical Heating Coil to the Surrounding Fluid.

An experimental study is reported on natural convection heat transfer from a helical heating coil to the surrounding fluid. The coil is heated electrically and the surrounding fluid is selected to be water. The range of parameters are: Rayleigh number, 879 ?£ Ra ?£ 780168, Prandtl number, 4.22 ?£ Pr ?£ 10.02, dimensionless coil diameter,7.69 ?£ Dave /d ?£ 10.77, number of coil rings, 2 ?£ N ?£ ...

متن کامل

Phosphorus K4 Crystal: A New Stable Allotrope

The intriguing properties of phosphorene motivate scientists to further explore the structures and properties of phosphorus materials. Here, we report a new allotrope named K4 phosphorus composed of three-coordinated phosphorus atoms in non-layered structure which is not only dynamically and mechanically stable, but also possesses thermal stability comparable to that of the orthorhombic black p...

متن کامل

The effect of Geometrical parameters on heat transfer coefficient in helical double tube exchangers

Helical coil heat exchangers are widely used in industrial applications ranging fromcryogenic processes, air-conditioning, and nuclear reactors to waste heat recovery due totheir compact size and high heat transfer coefficient. In this kind of heat exchangers, flowand heat transfer are complicated. This paper reports a numerical investigation of theinfluence of different parameters such as coil...

متن کامل

2D electronics: From graphene to transition metal dichalcogenides to layered and tubular group V allotropes*

If graphene had a band gap, it would probably be the optimum 2D system for electronics applications. Layered transition metal dichalcogenides (TMDs) with a robust intrinsic band gap appear as the next-best alternative. Only after a long search, however, optimum strategies have been devised to make low-resistance, ohmic contacts to TMDs [1]. In the meantime, a new class of 2D semiconductors has ...

متن کامل

Sensitivity Analysis and Stray Capacitance of Helical Flux Compression Generator with Multi Layer Filamentary Conductor in Rectangular Cross-Section

This paper presents an approach to calculate the equivalent stray capacitance (SC) of n-turn of the helical flux compression generator (HFCG) coil with multi layer conductor wire filaments (MLCWF) in the form of rectangular cross-section. This approach is based on vespiary regular hexagonal (VRH) model. In this method, wire filaments of the generator coil are separated into many very small simi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nano letters

دوره 16 12  شماره 

صفحات  -

تاریخ انتشار 2016