Fat-Suppressed and Distortion-Corrected MRI Near Metallic Implants
نویسندگان
چکیده
Introduction: The use of orthopedic implants including joint replacements and fixation devices is increasingly common, necessitating follow-up evaluation to assess possible complications such as loosening or infection. Due to metal-induced distortion and other artifacts on conventional MRI, follow-up is often limited to Xray images. With additional encoding and parallel imaging, MR images with minimal distortion can be acquired in subjects with metallic implants in reasonable scan times [1,2]. Here we achieve distortion-corrected imaging with fat suppression by integrating short TI inversion recovery (STIR) [3] with slice-encoding for metal artifact reduction (SEMAC) [2]. STIR offers fat suppression that is insensitive to susceptibility variations, so it is a robust choice for fat suppression near metal.
منابع مشابه
Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
PURPOSE To compare short tau inversion recovery (STIR) images with slice encoding for metal artifact correction (SEMAC)-corrected magnetic resonance imaging (MRI) of spectral presaturation with inversion recovery (SPIR) or inversion recovery (IR) at 3T in patients with metallic spinal instrumentation. METHODS Following institutional review board's approval, 71 vertebrae with interbody fixatio...
متن کاملNoise Reduction in Slice Encoding for Metal Artifact Correction Using Singular Value Decomposition
Introduction: MRI near metallic implants is often limited by severe artifacts. To obtain distortion-free MR images near metallic implants, SEMAC (slice encoding for metal artifact correction) [1] extends a view-angle-titling (VAT) [2] spin echo sequence with additional z phase encoding to resolve metal artifacts. Figure 1 illustrates that metal artifacts are corrected by combining the 3D data r...
متن کاملSEMAC: Slice Encoding for Metal Artifact Correction in MRI.
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each exci...
متن کاملMagnetic Resonance in Medicine 61:381–390 (2009) A Multispectral Three-Dimensional Acquisition Technique for Imaging Near Metal Implants
Metallic implants used in bone and joint arthroplasty induce severe spatial perturbations to the B0 magnetic field used for high-field clinical magnetic resonance. These perturbations distort slice-selection and frequency encoding processes applied in conventional two-dimensional MRI techniques and hinder the diagnosis of complications from arthroplasty. Here, a method is presented whereby mult...
متن کاملAdaptive Slice Encoding for Metal Artifact Correction
Introduction: Metallic implants can cause moderate or severe distortion artifacts in MR images depending on the shape, size, composition and orientation of the implant. Recentlyproposed methods correct image distortion due to susceptibility shifts near metallic implants by using excitation of limited bandwidths [1] or limited spatial slices [2], both followed by 3D imaging. Here we demonstrate ...
متن کامل