"Echocardiography in Nigeria: use, problems, reproducibility and potentials"

نویسندگان

  • Okechukwu S Ogah
  • Ademola T Adebanjo
  • Adedeji S Otukoya
  • Tarwanger J Jagusa
چکیده

BACKGROUND Although echocardiography is a useful and cost-effective technique for the detection of morphological and functional cardiac abnormalities, it has a main limitation in its subjectivity. Therefore the aim of the present study was to assess the intra-observer reproducibility and validity of 2-dimensional guided M-mode echo measurements at a Nigerian metropolitan Hospital. METHODS Standard echocardiographic examination was performed on twenty randomly selected patients (11 men and 9 women) aged 59.8 +/- 12.6 years in two different sessions seven days apart. RESULTS A good degree of intraobserver agreement was observed between test 1 and test 2. The correlation coefficient between the first and second studies ranged between 0.60 and 0.96; measurement errors between 0.050 and 0.205. CONCLUSION We would conclude that 2-dimensional guided M-mode measurements at echocardiography performed at our centre are reproducible with low intra-observer variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Theoretical Investigation of Corrosion Inhibitive Potentials of (E)-4-hydroxy-3-[(2,4,6-tribromophenyl)diazenyl]benzaldehyde on Mild Steel in Acidic Media

Corrosion of metal surfaces amongst other problems is one major disaster militating against proper functioning of the oil and gas and other manufacturing industries. To therefore lessen the risk, organic corrosion inhibitors have been applied to lessen the rate of corrosion and its effects. However, materials with optimal properties, better than content that allow corrosion are used for this em...

متن کامل

High Presence of Toxigenic Aspergillus spp. in Commercial Poultry Feeds in Ilaro, Nigeria

Background: Several health problems may be occurred due to consumption of mycotoxin-contaminated foods and feeds. The maize and oilseeds, as the main components of poultry feeds are susceptible to mould contamination and mycotoxin production. The aim of this study was to determine the presence of toxigenic Aspergillus spp. in poultry feeds from Ilaro, Nigeria. Methods: A total of 60 poultry fe...

متن کامل

A Multimodal Discourse Analysis of Some Visual Images in the Political Rally Discourse of 2011 Electioneering Campaigns in Southwestern Nigeria

This paper presented a multimodal discourse analysis of some visual images in the political rally discourse of 2011 electioneering campaigns in Southwestern Nigeria. The data comprised purposively selected political visual artefacts from political rallies across the six Southwestern States in Nigeria (Osun, Oyo, Ondo, Ekiti, Ogun, and Lagos). The data were analyzed using Halliday’s (1985) syste...

متن کامل

In vitro and in vivo antioxidant potentials of Alchornea floribunda leaf extract, fractions and isolated bioactive compounds

Objective: Alchornea floribunda leaves are widely used in ethnomedicine for the management of immuno-inflammatory disorders. We investigated the in vivo and in vitro antioxidant activity of the leaf extract, fractions and isolated compounds of A. floribunda.Materials and Methods: The ethyl acetate fraction of the methanol leaf extract was subjected to several chromatographic separations to isol...

متن کامل

Acute Toxicity Studies and Anti-plasmodial Potentials of Newbouldia laevis and Crateva adansonii in Plasmodium Berghei-infected Mice

Background: Newbouldia laevis and Crateva adansonii are popular plants used traditionally in the management of patients with malaria infection in Nigeria. In this study, the acute toxicity and anti-plasmodial effects of the leaf extracts of Newbouldia laevis and Crateva adansonii were investigated in mice. Methods: The Anti-plasmodial activities of both extracts were investigated individual...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2006