Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis.
نویسندگان
چکیده
Background The diagnostic accuracy of diffusion-weighted imaging (DWI) to detect prostate cancer is well-established. DWI provides visual as well as quantitative means of detecting tumor, the apparent diffusion coefficient (ADC). Recently higher b-values have been used to improve DWI's diagnostic performance. Purpose To determine the diagnostic performance of high b-value DWI at detecting prostate cancer and whether quantifying ADC improves accuracy. Material and Methods A comprehensive literature search of published and unpublished databases was performed. Eligible studies had histopathologically proven prostate cancer, DWI sequences using b-values ≥ 1000 s/mm2, less than ten patients, and data for creating a 2 × 2 table. Study quality was assessed with QUADAS-2 (Quality Assessment of diagnostic Accuracy Studies). Sensitivity and specificity were calculated and tests for statistical heterogeneity and threshold effect performed. Results were plotted on a summary receiver operating characteristic curve (sROC) and the area under the curve (AUC) determined the diagnostic performance of high b-value DWI. Results Ten studies met eligibility criteria with 13 subsets of data available for analysis, including 522 patients. Pooled sensitivity and specificity were 0.59 (95% confidence interval [CI], 0.57-0.61) and 0.92 (95% CI, 0.91-0.92), respectively, and the sROC AUC was 0.92. Subgroup analysis showed a statistically significant ( P = 0.03) improvement in accuracy when using tumor visual assessment rather than ADC. Conclusion High b-value DWI gives good diagnostic performance for prostate cancer detection and visual assessment of tumor diffusion is significantly more accurate than ROI measurements of ADC.
منابع مشابه
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملAccuracy of multiparametric MRI for prostate cancer detection: a meta-analysis.
OBJECTIVE The purpose of this diagnostic meta-analysis was to determine the diagnostic accuracy of multiparametric MRI for prostate cancer detection using anatomic T2-weighted imaging combined with two functional techniques: diffusion-weighted imaging (DWI) and dynamic contrast-enhanced MRI (DCE-MRI). MATERIALS AND METHODS We searched electronic databases, including MEDLINE, Embase, and the C...
متن کاملAutomated prostate cancer detection via comprehensive multi-parametric magnetic resonance imaging texture feature models
BACKGROUND Prostate cancer is the most common form of cancer and the second leading cause of cancer death in North America. Auto-detection of prostate cancer can play a major role in early detection of prostate cancer, which has a significant impact on patient survival rates. While multi-parametric magnetic resonance imaging (MP-MRI) has shown promise in diagnosis of prostate cancer, the existi...
متن کاملUsefulness of a Combined Approach of T1-Weighted, T2-Weighted, Dynamic Contrast-Enhanced, and Diffusion-Weighted Imaging in Prostate Cancer
PURPOSE We evaluated the value of a combined approach of T1-weighted (T1W) imaging, T2-weighted (T2W) imaging, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) for the detection of prostate cancer and extracapsular extension (ECE) in patients with prostate cancer by using pathologic data after radical prostatectomy. MATERIALS AND METHODS Fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta radiologica
دوره 59 1 شماره
صفحات -
تاریخ انتشار 2018