A comparative assessment of cephalometric errors.
نویسنده
چکیده
Measuring a cephalometric radiograph is an imprecise task, and the errors associated with this should be quantified and understood. The potential sources of error are outlined and the literature relating to the assessment of measurement errors is reviewed. Three techniques are examined: the error attributable to a single recording; its associated confidence limits; and the coefficient of reliability were the most commonly applied. Data from two error studies were pooled and used to compare the accuracy of 12 skeletal, dental, and soft tissue measurements, using various assessments of each of the three techniques. Within each group, the use of different mathematical criteria led to variation in the results; one method was totally unsuitable. As with all statistical procedures, a knowledge of the technique facilitates interpretation of the results. Some suggestions as to the most satisfactory approach to the estimation of measurement error in cephalometry are given.
منابع مشابه
Assessment of Image Distortion from Head Rotation in Lateral Cephalometry
BACKGROUND The patient's head can be slightly rotated sagitally vertically or transversely within the head holding device. Because of such improper positions due to the head rotation, an error can occur in cephalometric measurements. The purpose of this study was to identify the potential projection errors of lateral cephalometric radiograph due to head rotation toward X-ray film in the vertica...
متن کاملComparative study between conventional and digital radiography in cephalometric analysis Estudo comparativo entre radiografia convencional e digital na análise cefalométrica
Objective – Technological improvement is usually followed by comparisons between conventional and new. Those who work with radiographic assessment, such as cephalometric analysis for orthodontic diagnosis, have been living a new challenging and learning phase since the introduction of digital images. It is possible to obtain reproducible and clear images with digital radiography, but radiograph...
متن کاملAn Evaluation of Cellular Neural Networks for the Automatic Identification of Cephalometric Landmarks on Digital Images
Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital conversion of X-ray has been claimed to be the main problem. Therefore the aim of this investigation was to evaluate the accuracy of the Cellular Neural Networks approach for automatic l...
متن کاملCephalometric landmarks identification and reproducibility: a meta analysis.
To assess the magnitude of cephalometric landmarks identification error, we performed a Meta analysis on six pertinent studies. We outline the procedures used to compare and integrate the findings of these-studies. The results are a measure of systematic and random errors involved when locating landmarks on lateral head films. They are presented as standard mean errors and 95% confidence interv...
متن کاملTranslation Quality Assessment of English Equivalents of Persian Proper Nouns: A case of bilingual tourist signposts in Isfahan
Abstract This study evaluated the translation quality of English equivalents of Persian proper nouns in the tourist signs and bilingual boards in Isfahan. To find different errors in the translations of the bilingual boards and tourist signs, the data were collected directly by taking picture or writing exactly from the available tourist signs and bilingual boards. Then, the errors were assesse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of orthodontics
دوره 15 4 شماره
صفحات -
تاریخ انتشار 1993